"Nonclass" Errors (Cont'd) [ MPE/iX Error Messages Manual Volume II ] MPE/iX 5.5 Documentation
MPE/iX Error Messages Manual Volume II
"Nonclass" Errors (Cont'd)
Interpreting SYSGEN Messages and Error Codes (Continued)
Miscellaneous (MISC) Configurator Messages (Continued).
1000 MESSAGE **error** can't read MISC configuration data
CAUSE SYSGEN encountered an error in trying to read the
miscellaneous configuration data file.
ACTION Refer to the file system error.
-------------------------------------------------------------
1001 MESSAGE **error** system ID too long
CAUSE You have entered a system ID that has too many
characters. The limit is eight.
ACTION Reenter the command with the proper system ID
value.
-------------------------------------------------------------
1005 MESSAGE **error** can't display parameter ! in misc
display table
CAUSE SYSGEN has encountered an error in trying to
display this parameter from the miscellaneous
configuration data file.
ACTION Contact software personnel responsible for updating
and maintaining these files.
-------------------------------------------------------------
1007 MESSAGE **error** prompt too long
CAUSE You have requested a string for the prompt that has
too many characters for the configuration file
entry.
ACTION Reenter the command with a shorter string.
-------------------------------------------------------------
1008 MESSAGE **error** Can't get an extra data segment for rin
table
CAUSE Same as message.
ACTION Refer to system error message for action.
-------------------------------------------------------------
1009 MESSAGE **error** Can't initialize extra data segment for
rin table
CAUSE SYSGEN has encountered an internal system error in
attempting to initialize the new space granted for
RIN table expansion.
ACTION Refer to system or file system error for action.
-------------------------------------------------------------
1010 MESSAGE **error** Can't list rins
CAUSE SYSGEN has encountered a system error in trying to
list the RINs as requested.
ACTION Refer to system error or file system error message
for the action to undertake.
-------------------------------------------------------------
1011 MESSAGE **error** Can't alter extra data segment for rin
table
CAUSE SYSGEN has encountered an internal system error in
trying to make changes in the new area of the RIN
table.
ACTION Refer to system error message for the action.
-------------------------------------------------------------
1012 MESSAGE **error** Can't read from extra data segment for
rin table
CAUSE SYSGEN has encountered a system error in trying to
read the RIN table in trying to process your
command.
ACTION Refer to the system or file system error for the
action.
-------------------------------------------------------------
1013 MESSAGE **error** Can't free extra data segment for rin
table
CAUSE SYSGEN has encountered a system error in trying to
release a portion of the RIN table in trying to
process your command.
ACTION Refer to the system error for the action.
-------------------------------------------------------------
1014 MESSAGE **error** Can't get rin table size from extra
data segment
CAUSE SYSGEN has encountered as error in trying to obtain
the RIN table size while processing your command.
ACTION Refer to the system error for action.
-------------------------------------------------------------
1020 MESSAGE **error** can't write MISC configuration data
CAUSE SYSGEN has encountered an error while trying to
write to the miscellaneous configuration data file.
ACTION Refer to the system or file systems error for
action.
-------------------------------------------------------------
1021 MESSAGE **error** Only the factory can change this.
CAUSE You have attempted to change an item in the
miscellaneous configuration data that is reserved
for factory maintenance.
ACTION None.
-------------------------------------------------------------
1025 MESSAGE **error** sysprompt string in MISC configuration
corrupt!
CAUSE SYSGEN has encountered an error in trying to obtain
the system prompt string value.
ACTION Contact software personnel responsible for updating
and maintaining these files.
-------------------------------------------------------------
1026 MESSAGE **error** ciprompt string in MISC configuration
corrupt!
-------------------------------------------------------------
1030 MESSAGE **error** configuration files incompatable with
this version of SYSGEN
-------------------------------------------------------------
1031 MESSAGE SYSGEN version = ! Config files version = !
-------------------------------------------------------------
Logging (LOG) Configurator Messages.
-------------------------------------------------------------
0500 MESSAGE **warning** of logging processes is smaller than
LID table.
CAUSE Reducing the value of nlogprocs below what is
currently used the LID table to be rebuilt from
scratch, losing any current logging IDs (only
effect if UPDATE CONFIG or INSTALL done with tape
made from this config).
ACTION If you want logging IDs preserved, raise the value.
Otherwise, ignore it.
-------------------------------------------------------------
0501 MESSAGE LID table on tape will be empty!
-------------------------------------------------------------
1000 MESSAGE **error** can't read LOG configuration data
CAUSE SYSGEN cannot read the configuration data file LOGP
for whatever reason. Program dies.
ACTION Refer to the file system error for action to take.
-------------------------------------------------------------
1001 MESSAGE **error** can't write LOG configuration data
CAUSE SYSGEN cannot write the configuration data file
LOGP for whatever reason. Program dies.
ACTION Refer to the file system error for action to take.
-------------------------------------------------------------
MPE/iX 5.5 Documentation