HP 3000 Manuals

"Nonclass" Errors (Cont'd) [ MPE/iX Error Messages Manual Volume II ] MPE/iX 5.5 Documentation


MPE/iX Error Messages Manual Volume II

"Nonclass" Errors (Cont'd) 

Interpreting SYSGEN Messages and Error Codes (Continued) 

Miscellaneous (MISC) Configurator Messages (Continued).   

1000         MESSAGE    **error** can't read MISC configuration data

           CAUSE      SYSGEN encountered an error in trying to read the
                      miscellaneous configuration data file.

           ACTION     Refer to the file system error.

-------------------------------------------------------------

1001         MESSAGE    **error** system ID too long

           CAUSE      You have entered a system ID that has too many
                      characters.  The limit is eight.

           ACTION     Reenter the command with the proper system ID
                      value.

-------------------------------------------------------------

1005         MESSAGE    **error** can't display parameter ! in misc
                      display table

           CAUSE      SYSGEN has encountered an error in trying to
                      display this parameter from the miscellaneous
                      configuration data file.

           ACTION     Contact software personnel responsible for updating
                      and maintaining these files.

-------------------------------------------------------------

1007         MESSAGE    **error** prompt too long

           CAUSE      You have requested a string for the prompt that has
                      too many characters for the configuration file
                      entry.

           ACTION     Reenter the command with a shorter string.

-------------------------------------------------------------

1008         MESSAGE    **error** Can't get an extra data segment for rin
                      table

           CAUSE      Same as message.

           ACTION     Refer to system error message for action.

-------------------------------------------------------------

1009         MESSAGE    **error** Can't initialize extra data segment for
                      rin table

           CAUSE      SYSGEN has encountered an internal system error in
                      attempting to initialize the new space granted for
                      RIN table expansion.

           ACTION     Refer to system or file system error for action.

-------------------------------------------------------------

1010         MESSAGE    **error** Can't list rins

           CAUSE      SYSGEN has encountered a system error in trying to
                      list the RINs as requested.

           ACTION     Refer to system error or file system error message
                      for the action to undertake.

-------------------------------------------------------------

1011         MESSAGE    **error** Can't alter extra data segment for rin
                      table

           CAUSE      SYSGEN has encountered an internal system error in
                      trying to make changes in the new area of the RIN
                      table.

           ACTION     Refer to system error message for the action.

-------------------------------------------------------------

1012         MESSAGE    **error** Can't read from extra data segment for
                      rin table

           CAUSE      SYSGEN has encountered a system error in trying to
                      read the RIN table in trying to process your
                      command.

           ACTION     Refer to the system or file system error for the
                      action.

-------------------------------------------------------------

1013         MESSAGE    **error** Can't free extra data segment for rin
                      table

           CAUSE      SYSGEN has encountered a system error in trying to
                      release a portion of the RIN table in trying to
                      process your command.

           ACTION     Refer to the system error for the action.

-------------------------------------------------------------

1014         MESSAGE    **error** Can't get rin table size from extra
                      data segment

           CAUSE      SYSGEN has encountered as error in trying to obtain
                      the RIN table size while processing your command.

           ACTION     Refer to the system error for action.

-------------------------------------------------------------

1020         MESSAGE    **error** can't write MISC configuration data

           CAUSE      SYSGEN has encountered an error while trying to
                      write to the miscellaneous configuration data file.

           ACTION     Refer to the system or file systems error for
                      action.

-------------------------------------------------------------

1021         MESSAGE    **error** Only the factory can change this.

           CAUSE      You have attempted to change an item in the
                      miscellaneous configuration data that is reserved
                      for factory maintenance.

           ACTION     None.

-------------------------------------------------------------

1025         MESSAGE    **error** sysprompt string in MISC configuration
                      corrupt!

           CAUSE      SYSGEN has encountered an error in trying to obtain
                      the system prompt string value.

           ACTION     Contact software personnel responsible for updating
                      and maintaining these files.

-------------------------------------------------------------

1026         MESSAGE    **error** ciprompt string in MISC configuration
                      corrupt!

-------------------------------------------------------------

1030         MESSAGE    **error** configuration files incompatable with
                      this version of SYSGEN

-------------------------------------------------------------

1031         MESSAGE    SYSGEN version = ! Config files version = !

-------------------------------------------------------------

Logging (LOG) Configurator Messages.   

-------------------------------------------------------------

0500         MESSAGE    **warning** of logging processes is smaller than
                      LID table.

           CAUSE      Reducing the value of nlogprocs below what is
                      currently used the LID table to be rebuilt from
                      scratch, losing any current logging IDs (only
                      effect if UPDATE CONFIG or INSTALL done with tape
                      made from this config).

           ACTION     If you want logging IDs preserved, raise the value.
                      Otherwise, ignore it.

-------------------------------------------------------------

0501         MESSAGE    LID table on tape will be empty!

-------------------------------------------------------------

1000         MESSAGE    **error** can't read LOG configuration data

           CAUSE      SYSGEN cannot read the configuration data file LOGP
                      for whatever reason.  Program dies.

           ACTION     Refer to the file system error for action to take.

-------------------------------------------------------------

1001         MESSAGE    **error** can't write LOG configuration data

           CAUSE      SYSGEN cannot write the configuration data file
                      LOGP for whatever reason.  Program dies.

           ACTION     Refer to the file system error for action to take.

-------------------------------------------------------------



MPE/iX 5.5 Documentation