User Errors (1000-1499) 

1167         MESSAGE    Expected NMXL file.  File "!" is a CM file
                      (LINKERR 1167)

           CAUSE      The Link Editor encountered a compatibility mode
                      file when linking and shared data was enabled.

           ACTION     Make sure LKSHAREDATA is unset or set to FALSE
                      before attempting to link with compatibility mode
                      files.

Warning Messages (1500-1999) 

1562         MESSAGE    SYMBOL "!1" IS HIDDEN/NOT HIDDEN IN DIFFERENT
                      MODULES. HIDING IT (LINKWARN 1562)

           CAUSE      The Link Editor encountered a hidden and non-hidden
                      version of the same symbol during the link.

           ACTION     Make sure all definitions in the object modules you
                      are linking with are hidden or make sure that all
                      definitions are not hidden.  A mismatch of hidden
                      and unhidden symbols causes the Link Editor to hide
                      all occurrences it sees.

Language Subsystem Errors (3000-3999) 

3060         MESSAGE    REFERENCE TO "!" IN FILE "!" NEEDS 3-INSTRUCTION
                      SEQUENCE -- USE +k OR $MORE_GLOBALS$ TO RECOMPILE
                      (LINKERR 3060)

           CAUSE      DXRT limit of approximately 2k was hit.  There are
                      too many data imports and/or too many imports
                      requiring multiple DXRT slots.

           ACTION     Recompile with the +k option or $MORE_GLOBALS$
                      pragma to compile for 3-instruction load and store
                      sequences.  The DXRT can be bigger than 2k because
                      far away slots can be reached by using the extra
                      instruction generated.