HP 3000 Manuals

SORTEND [ MPE/iX Intrinsics Reference Manual ] MPE/iX 5.0 Documentation


MPE/iX Intrinsics Reference Manual

SORTEND 

NM and CM callable.

Closes the scratch file and restores the data stack to its original
state.

Syntax 
_____________________________________
|                                   |
|                                   |
|     SORTEND;                      |
_____________________________________

            

Operation Notes 

Signals the beginning of the SORT program if the SORTOUTPUT intrinsic is
not called.

Required if SORTINIT is called.  Call SORTEND either after all calls to
the output file are completed by the SORTINIT intrinsic, or after all
calls to the SORTOUTPUT intrinsic are completed.


NOTE If you are coding a CM application, you must call SORTEND in the same routine in which you call the SORTINIT intrinsic. This is not the case when you code an NM application.
Condition Codes CCE (2) Request granted. No error occurred during the SORT program. The value of the failure parameter of the SORTINIT intrinsic is set to false. CCG (0) Not returned. CCL (1) Request denied. An error occurred during the SORT program. The value of the failure parameter of the SORTINIT intrinsic is set to true. Related Information Intrinsics HPSORT, HPMERGE Commands None Manuals SORT-MERGE/XL Programmer's Guide (32650-90080)


MPE/iX 5.0 Documentation