SWITCHBACK 

Initiates the switchback of volume sets from the alternate system to the
home system.  SPU Switchover/iX is not a part of the 900 Series HP 3000
Computer System Fundamental Operating Software and must be purchased
separately.

Syntax 

SWITCHBACK [FROM=]altsystem[[TO=]homesystem]

Parameters 

altsystem             Indicates the name of the alternate system as
                      specified in the SYSTEM APAIR command.  When the
                      operator enters the command FROM=altsystem, all
                      volume sets specified in the configuration as
                      belonging to homesystem are switched back from
                      altsystem and mounted to homesystem.  Altsystem can
                      be operative or inoperative when the command is
                      entered.

homesystem            Indicates the name of the system whose home volume
                      sets were switched over to the alternate system.
                      When the operator enters the command TO=homesystem,
                      the switchable volume sets specified in the
                      configuration that belong to homesystem are
                      switched back from altsystem and mounted on
                      homesystem.

Operation Notes 

Before an operator can execute the command, you must assign homesystem as
the home system and altsystem as the alternate system in the SPU
configuration file.

If a hardware failure occurred, the operator must enter the command from
the home system console after a successful reboot; the system is then
ready to receive the volume sets defined using the SYSGEN utility AVOLSET
command.


NOTE This command is entered on the system where the volume sets are going to.
The operator can enter the command within a session, job, program, or in BREAK. The following requirements apply before an operator can enter the SWITCHBACK command: * The SPU Switchover/iX environment must be properly configured using the SYSGEN utility SPU commands. * The switchable nonsystem volume sets must be closed on the alternate system. * The SWITCHOVER command must have been previously entered from the alternate system. * The operator must have OP or SM capability. Use This command may be issued from a session, job, or in BREAK mode. Example The following command is issued from the home system (Alpha) console as shown: : SWITCHBACK FROM=BETA TO=ALPHAReturn The home system (Alpha) responds by displaying the following message once on the home system (Alpha) and alternate system (Beta) consoles: /00:00/nn/SPU SWITCHBACK FROM BETA TO ALPHA STARTING. You must respond to the following message that is displayed on the home system (Alpha) when switchback has successfully completed: /00:00/nn/ACKNOWLEDGE SPU SWITCHBACK FROM BETA TO ALPHA COMPLETE (Y/N)? =REPLY nn,YReturn This message is displayed every 30 seconds until the operator acknowledges completion of the switchback. The operator must respond to this message on the home system (Alpha). The reply has no effect except to stop the repeating message. The following message appears once on the alternate system (Beta) console: /00:00/nn/SPU SWITCHBACK FROM BETA TO ALPHA COMPLETE. Related Information Commands SPUCONTROL, SWITCHOVER Manuals SPU Switchover/XL User's Guide (36378-90001) System Startup, Configuration, and Shutdown Reference Manual (32650-90042)