LINK [ MPE/iX Commands Reference Manual Volume I ] MPE/iX 5.0 Documentation
MPE/iX Commands Reference Manual Volume I
LINK
Creates an executable program file by merging the relocatable object
modules from all the files in its FROM= parameter. Those files may
correspond to object files, relocatable files, or a combination of them.
It also searches any relocatable libraries mentioned in the RL= parameter
list and merges any modules within those libraries that resolve an
external reference. (Native Mode)
Syntax
LINK [FROM=file[,file...][;TO=destfile]]
[;RL=rlfile[,rlfile...]...][;XL=xlfile[,xlfile...]...]
[;CAP=caplist][;NMSTACK=nmstacksize] [;NMHEAP=nmheapsize][;UNSAT=unsatname]
[;PARMCHECK=checklevel][;ENTRY=entryname] [;NODEBUG][;MAP][;SHOW]
[;PRIVLEV=priv_level] [;PRI=pri_level] [;MAXPRI=max_pri_level] [;SHARE]
NOTE This command follows the optional MPE/iX command line syntax.
Refer to "Optional Format for MPE/iX Commands" at the beginning of
this chapter.
Parameters
file The name of an object file or a relocatable library
file. It may be any binary file of type NMOBJ or
NMRL. All relocatable objects in the FROM=
specified list are merged to form the program file
specified by destfile. If you omit this parameter,
LINK merges the object modules in the file
$OLDPASS.
The FROM=, RL=, and XL= parameters allow a series
of file names. You may name each file
individually, or you may provide an indirect file
by preceding that file's name with the caret symbol
(^).
destfile The name of the program file (type NMPRG) where
LINK places the resulting executable object module.
If destfile does not exist, LINK creates a new one
for you. If destfile does exist, it is destroyed
and replaced by the object module created by the
current link operation.
rlfile The name of a relocatable library file (type NMRL)
that resolves an external reference made by an
object module in the FROM= file list. LINK
searches the relocatable libraries in the RL list
in the order in which you list them. If a module
from one library calls a routine in another library
and then that routine in turn refers to a module in
the first library, you may need to include the
first library twice so that LINK can resolve this
"circular" reference.
The FROM=, RL=, and XL= parameters allow a series
of file names. You may name each file
individually, or you may provide an indirect file
by preceding that file's name with the caret symbol
(^).
xlfile The name of an executable library (type NMXL). The
loader searches every executable library in the XL
list in an attempt to resolve external references
that remain in a program file.
caplist The list of capability attributes to be assigned to
the program file. The program runs only if the
group and account have matching capabilities. (The
system manager or account manager assigns these
capabilities to your group and account.)
Permissible values are:
BA = Local Batch Access
IA = Interactive Access
PM = Privileged Mode
MR = Multiple RINs
DS = Extra Data Segments
PH = Process Handling
If you omit this parameter, the BA and IA
capabilities are assigned to the program file by
default.
nmstacksize The maximum size, in bytes, to which the NM stack
may grow. This must be a decimal number. The
default is zero, which instructs MPE/iX to assign a
system-defined constant as the value of
nmstacksize.
nmheapsize The maximum size, in bytes, to which the NM heap
may grow. This must be a decimal number. The
default is -1, which instructs the command to
assign a system-defined constant as the value of
nmheapsize.
unsatname The name of a procedure that the loader substitutes
in place of any external reference that cannot be
resolved in a program file. If you omit this
parameter and any external references remain
unresolved, the loader reports a load-time error.
checklevel An integer specifying the maximum level of checking
that LINK performs in binding external references
to procedures. All checking levels that are
indicated in external references and procedure
definitions are reduced (but never increased) to
the specified level. If you omit this parameter,
LINK sets the value to 3.
Permissible values for checklevel are defined in
table 2-17.
Table 2-17. Checklevel Values
---------------------------------------------------------------------------------------------
| | |
| 0 | No parameter check. |
| | |
- -
| | |
| 1 | Check of the symbol type descriptor. |
| | |
- -
| | |
| 2 | Perform Level 1 checking, then check the number of arguments that the |
| | import procedure passed against the minimum and maximum range that were |
| | declared in the export procedure. |
| | |
- -
| | |
| 3 | Perform Level 2 checking, then check the type of each argument that was |
| | passed. |
| | |
---------------------------------------------------------------------------------------------
If the checking level is restricted (reduced) and reportable type errors
are detected, they are reported not as errors but as warnings.
entryname The name (label) of the point within a program
where execution begins. When you omit this
parameter, the loader begins execution from the
primary program entry point (which corresponds to a
program's main procedure or outer block). However,
by including the ENTRY= option, you may override
this default value and begin execution from the
specified entry point. If the loader fails to find
a symbol that matches the entry point name, it
reports a load-time error.
NODEBUG Strips all symbolic debugging information from the
resulting program file. If you omit this
parameter, the file contains debugging information
if the source file was compiled with this option.
MAP Prints a symbol map to the list file, LINKLIST.
SHOW Displays the name of each object module as it is
being merged into the program file. You may
include this option to verify the order in which
LINK processes each module.
priv_level Determines the privilege level used by the
executable program file. This parameter changes
the privilege level of all procedures in the symbol
and export tables (of the relocatable object file)
that were set during compilation.
The values for priv_level are:
0 system level access
1 unused
2 privileged level access
3 user level access
The default is that privilege levels are set during
compilation.
pri_level Specifies the execution priority that the program
will have at run time. The pri_level has to be one
of BS, CS, DS, ES, or a number between 100 and 255
inclusive. This value can be overridden by the
PRI= keyword on the RUN command.
max_pri_level Specifies the maximum execution priority that the
program can have at run time. The max_pri_level
has to be one of BS, CS, DS, ES, or a number
between 100 and 255 inclusive.
SHARE Specifies that data symbols should be exportable
and importable (shared) in the resulting executable
library.
Operation Notes
The Link Editor uses $STDINX, $STDIN, and $STDLIST as standard files.
The Link Editor reads its commands from $STDINX. For interactive sessions
this is the terminal keyboard. For a batch job, it is the job stream
file.
You can redirect $STDINX to another file. The file must be an unnumbered
ASCII file containing valid HP Link Editor/iX commands. Enter a RUN
command with the STDIN option. For example, to use the file SCRIPT as
the standard input file, enter the command:
RUN LINKEDIT.PUB.SYS;STDIN=SCRIPT
If you start the Link Editor using the LINK command, or if you execute it
by passing a command in the INFO string of the RUN command, $STDINX is
not used. Instead, the single command is executed and the Link Editor
terminates.
The Link Editor writes all prompts, error messages, and other information
to $STDLIST. During an interactive session, this is your terminal. For a
batch job, the output spoolfile is used.
You can use another device for $STDLIST. Use the RUN command with the
STDLIST option. Note that when you do this interactively, the command
prompts do not appear on the screen. For example, to send the Link
Editor output to the printer:
FILE LINKOUT;DEV=LP
RUN LINKEDIT.PUB.SYS;STDLIST=*LINKOUT
Link Editor listings and maps are sent to the file LINKLIST, not to
$STDLIST. The listings and maps sent to LINKLIST are:
* The symbol map produced by the MAP option of the LINK command.
* The listing produced by the LISTPROG command.
* The listing produced by the LISTOBJ command.
* The listing produced by the LISTRL command.
* The listing produced by the MAP option of the ADDXL command.
* The listings produced by the LISTXL command.
LINKLIST output goes to $STDLIST. But you can redirect it to another file
or device by using the FILE command. To send the listing of the
relocatable library LIBRL to the printer:
FILE LINKLIST;DEV=LP
LINKEDIT
LinkEd> LISTRL RL=LIBRL
LinkEd> EXIT
Use
This command may be issued from a session, job, or program, but not in
BREAK. Pressing Break suspends the execution of this command. Entering
the RESUME command continues the execution.
Examples
This command merges the object modules from the OBJCODE and places them
into the program EXECPROG. It assigns a program stack of 50,000 bytes and
requests LINK to build a map and display the name of each object module
as it is being linked.
LINK FROM=OBJCODE;TO=EXECPROG;NMSTACK=50000;MAP;SHOW
The following command merges the object modules from the OBJCODE into
program file EXECPROG and searches the relocatable libraries LINEDRAW and
ARCDRAW to resolve external references. The resulting program file can
be executed only in batch mode by anyone with user mode access.
LINK FROM=OBJCODE;TO=EXECPROG;RL=LINEDRAW,ARCDRAW;CAP=BA
To link module A and module MAIN and share data so that the data symbols
in the program file myprog can be exported and imported to and from the
executable library MYXL, enter:
LINK FROM=A,MAIN; TO=MYPROG; SHARE; RL=LIBCSHR.LIB.SYS; XL=MYXL
Related Information
Commands RUN, XEQ, LINKEDIT Utility
Manuals HP Link Editor/XL Reference Manual (32650-90030)
HP Link Editor/iX Technical Addendum (32650-90476