HP 3000 Manuals

MOUNT [ Volume Management ] MPE/iX 5.0 Documentation


Volume Management

MOUNT 

The MOUNT command mounts a disk volume making it accessible to DISCUTIL.
If an LDEV represents a disk and the device is responding, DISCUTIL
attempts to mount the volume.  Once a new volume has been mounted, it is
available to DISCUTIL. Only volumes that have been initialized as a
volume MASTER or MEMBER can be mounted.

Task 

Mounts a volume.

Capability 

No special capability required.

Syntax 

     MOUNT [LDEV=] ldev 

Parameter 

ldev                  A number from 1 to 100 specifying the logical
                      device number of the volume to be mounted.
                      Required.

Example 

This example shows how to make a volume accessible to DISCUTIL.

   1.  Use the DSTAT command to determine the state of the volume.

   2.  Use the MOUNT command to mount the volume.
________________________________________________________
|                                                      |
|                                                      |
|      discutil>DSTAT                                  |
|                                                      |
|                                                      |
|      LDEV-TYPE   STATUS   VOLUME (VOLUME SET - GEN)  |
|      ---------   ------   -------------------------- |
|      11-079350   MEMBER   BVOL1          (BSET-0)    |
|      12-079350   MEMBER   BVOL2          (BSET-0)    |
|                                                      |
|      discutil> MOUNT 13                              |
|                                                      |
|      *Note: VOLUME MOUNTED ON LDEV 13                |
|                                                      |
|      discutil>DSTAT                                  |
|                                                      |
|                                                      |
|      LDEV-TYPE   STATUS   VOLUME (VOLUME SET - GEN)  |
|      ---------   ------   -------------------------- |
|      11-079350   MEMBER   BVOL1          (BSET-0)    |
|      12-079350   MEMBER   BVOL2          (BSET-0)    |
|      13-079350   MEMBER   BVOL3          (BSET-0)    |
|                                                      |
|                                                      |
________________________________________________________

            



MPE/iX 5.0 Documentation