Utility Error Messages (contd) 

Utility Program Conditional Messages (contd) 

MESSAGE               INCOMPLETE REMOTE PART

CAUSE                 The period following the rusername was missing, or
                      the raccountname was missing, or the raccountname 
                      was followed by a comma and the rgroupname was
                      missing.

ACTION                Use the EDITOR to change the HELLO command.

---------------------------------------------------------------

MESSAGE               INSUFFICIENT DISC SPACE

CAUSE                 The amount of disk space required for the database
                      is not available on the system.

ACTION                Consult with the system manager about disk space
                      requirements.

---------------------------------------------------------------

MESSAGE               INSUFFICIENT VIRTUAL MEMORY

CAUSE                 Not enough virtual memory is available to open and
                      access the database.

ACTION                Try running the utility later when the system is
                      not as busy.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--CURRENT TRANSACTION COUNT IS
                      NEGATIVE

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--DATABASE CONTAINS INVALID LOGGING
                      IDENTIFIER

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--DATABASE SHOULD NOT BE OPEN AT THIS
                      TIME

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--DBBEGIN FOUND PROCESS ALIVE, BUT
                      TRAN STATE INACTIVE

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--EXPECTED DATABASE TO BE OPEN FOR
                      THIS PROCESS

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--FOPEN FAILS IN F'HEADLOG

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--FREADLABEL FAILS IN F'HEADLOG

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--HEAP STAGING AREA OVERFLOWED

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--INVALID DATABASE TABLE ADDRESS

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--INVALID DBTAB'PROC'TAIL

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--INVALID PASSWORD FOR DATABASE
                      LOGGING IDENTIFIER

CAUSE                 Log password does not correspond with the log
                      identifier in the log file.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--INVALID PROCTABLE INDEX FOUND IN
                      PROC'ACTIVELINK

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--INVALID RECOVERY TABLE ADDRESS

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--LOGID'TO'FNAME FAILURE

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--NO PROCESS TABLE ENTRY EXISTS

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--PROBLEM RETURNING HEAP

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--PROCESS NOT IN PROCESS TABLE

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--PROCESS TABLE IS FULL

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--RECORD TABLE IS FULL

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INTERNAL ERROR--UNABLE TO ALLOCATE THE HEAP

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INVALID ACCESS CLASS NUMBER

CAUSE                 The access class should be a number between 1 and
                      63.

ACTION                Reenter with a valid access class number.

---------------------------------------------------------------

MESSAGE               INVALID CHARACTER IN PASSWORD

CAUSE                 Password does not consist of allowed characters.

ACTION                Check the password specified and reenter the
                      command.

---------------------------------------------------------------

MESSAGE               INVALID COMMAND

CAUSE                 Command is unknown to the utility.

ACTION                Check spelling or see manual for legal commands.

---------------------------------------------------------------

MESSAGE               INVALID CONTENTS OF ASCII ACCESS FILE
                      ACTIVATION / DEACTIVATION FAILED

CAUSE                 The file specified is either

                         1.  Not a database-access file, or

                         2.  It does not contain the valid format and
                             parameters.

ACTION                Either

                         1.  Verify the correct database-access file, or

                         2.  Use EDITOR to make the required changes and
                             try accessing again.

---------------------------------------------------------------

MESSAGE               INVALID DATA BASE CONTROL BLOCK

CAUSE                 TurboIMAGE/XL encountered an inconsistency in the
                      control blocks.

ACTION                Contact your system engineer.

---------------------------------------------------------------

MESSAGE               INVALID DATA BASE ACCESS FILE NAME

CAUSE                 The file name or database name must be 1 to 6
                      characters starting with a letter.

ACTION                Reenter the command with the correct name.

---------------------------------------------------------------

MESSAGE               INVALID DATA BASE NAME

CAUSE                 The file name or database name must be 1 to 6
                      characters starting with a letter.

ACTION                Reenter the command with the correct name.

---------------------------------------------------------------

MESSAGE               INVALID DATA BASE NAME OR ACCESS FILE NAME

CAUSE                 The file name or database name must be 1 to 6
                      characters starting with a letter.

ACTION                Reenter the command with the correct name.

---------------------------------------------------------------

MESSAGE               INVALID DB INTRINSIC CODE IN LOG RECORD CODE FIELD

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INVALID DELIMITER

CAUSE                 The command or a space is incorrectly positioned.

ACTION                Use HELP to check command syntax and reenter the
                      command.

---------------------------------------------------------------

MESSAGE               INVALID FIRST LOG FILE NAME

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INVALID FIRST LOG FILE SEQUENCE NUMBER

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INVALID FIRST LOG FILE TIMESTAMP

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INVALID IMAGE LOG RECORD DETECTED

CAUSE                 DBRECOV encountered an undefined log record code.

ACTION                Notify the system manager and HP Support
                      Representative.

---------------------------------------------------------------

MESSAGE               INVALID LANGUAGE

CAUSE                 Language name or number has invalid characters.

ACTION                Retype the correct language name or number.

---------------------------------------------------------------

MESSAGE               INVALID LOG CODE IN LOG RECORD

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INVALID LOG DEVICE TYPE IN LOG RECORD

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INVALID LOG FILE DEVICE TYPE

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               INVALID MAINTENANCE WORD

CAUSE                 An incorrect maintenance word was used.

ACTION                Check the maintenance word specified and reenter
                      the command.

---------------------------------------------------------------

MESSAGE               INVALID NUMBER OF BUFFERS SPECIFIED

CAUSE                 The number of buffers must be between 4 and 255.

ACTION                Reenter DBUTIL >>SET command with a valid number.

---------------------------------------------------------------

MESSAGE               INVALID NUMBER OF USERS SPECIFIED

CAUSE                 The minimum number of users allowed is 1 and the
                      maximum is 120.  The ranges of users specified must
                      be in ascending order.

ACTION                Reenter DBUTIL >>SET command with a valid number.

---------------------------------------------------------------

MESSAGE               INVALID PARAMETER

CAUSE                 You specified an incorrect parameter.

ACTION                Use HELP to check the command format and reenter
                      the command.

---------------------------------------------------------------

MESSAGE               INVALID PASSWORD FOR DATA BASE LOGGING IDENTIFIER

CAUSE                 Log password does not correspond with the log
                      identifier used with the GETLOG command.

ACTION                Use DBUTIL to set the valid log identifier password
                      into the database.

---------------------------------------------------------------

MESSAGE               INVALID SUBSYSTEM ACCESS FLAG IN ROOT FILE

CAUSE                 TurboIMAGE/XL detected an invalid value for the
                      subsystem access in the root file.  Valid accesses
                      are READ, R/W, and NONE.

ACTION                Reset the subsystem access flag using DBUTIL >>SET
                      command.

---------------------------------------------------------------

MESSAGE               INVALID TRANSACTION SEQUENCE DETECTED

CAUSE                 Internal error.  The transaction numbers are not
                      consecutive.

ACTION                Notify your system manager and HP Support
                      Representative.

---------------------------------------------------------------

MESSAGE               INVALID (x) IN COLUMN y 

CAUSE                 The x represents the invalid character found in
                      column y.

ACTION                Use the EDITOR to change the database-access file
                      record which returns the error message.

---------------------------------------------------------------

MESSAGE               LANGUAGE MUST NOT BE LONGER THAN 16 CHARACTERS

CAUSE                 The language name is too long.

ACTION                Retype the correct language name.

---------------------------------------------------------------

MESSAGE               LANGUAGE NOT SUPPORTED

CAUSE                 The language is not supported on your system or is
                      not a valid language name.

ACTION                Check with your system manager for the
                      configuration of the language, or enter a valid
                      language name or number.

---------------------------------------------------------------

MESSAGE               LESS THAN 3 RECORDS IN FILE!

CAUSE                 The database-access file does not contain a FILE,
                      DSLINE, and HELLO command.

ACTION                Use the EDITOR to create the missing records.

---------------------------------------------------------------

MESSAGE               LOCAL ACCT NAME IS TOO LONG

CAUSE                 lacctname is more than eight characters.

ACTION                Use the EDITOR to change the lacctname.

---------------------------------------------------------------

MESSAGE               LOCAL GROUP NAME IS TOO LONG

CAUSE                 lgroupname has more than eight characters.

ACTION                Use the EDITOR to change the lgroupname.

---------------------------------------------------------------

MESSAGE               LOCAL USER NAME TOO LONG

CAUSE                 lusername has nore than eight characters.

ACTION                Use EDITOR to change the lusername.

---------------------------------------------------------------

MESSAGE               LOG BUFFER OVERFLOW

CAUSE                 There is insufficient buffer space to build the log
                      record.

ACTION                Notify the system manager and HP Support
                      Representative.

---------------------------------------------------------------

MESSAGE               LOG BUFFER OVERFLOW DURING GET NEXT LOGICAL LOG
                      RECORD

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               LOG FILE AND DATABASE IDs DO NOT MATCH

CAUSE                 Internal error.  Database is not using the correct
                      log file.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               LOGFILE AND DATA BASE LOGID'S DO NOT MATCH

CAUSE                 The restored database does not match the log file.

ACTION                Be sure the log file and the backup database are
                      properly attached.

---------------------------------------------------------------

MESSAGE               LOG FILE HEADER RECORD IS NOT FIRST RECORD

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               LOGFILE IS EMPTY

CAUSE                 The log file has no records.

ACTION                Be sure you have correctly identified the log file.

---------------------------------------------------------------

MESSAGE               LOG FILE OPEN FAILED

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               LOG FILE RECORD SIZE IS IMPROPER

CAUSE                 Internal error.  The records are not 256 bytes with
                      a fixed length.

ACTION                Be sure this file is actually a log file.  Contact
                      your system manager.

---------------------------------------------------------------

MESSAGE               LOGID:logid IS INVALID

CAUSE                 The database logid has been removed from the MPE/iX
                      table.

ACTION                Set the database to an existing logid, or use the
                      GETLOG command to establish the database logid on
                      the MPE/iX table.

---------------------------------------------------------------

MESSAGE               LOGID MUST NOT BE LONGER THAN 8 CHARACTERS

CAUSE                 The logid name is too long.

ACTION                Retype the correct logid to set into the database.

---------------------------------------------------------------

MESSAGE               LOGID PASSWORD IS INCORRECT

CAUSE                 The password has been altered, or you are using the
                      wrong password.

ACTION                Set the logid with the correct password into the
                      database.

---------------------------------------------------------------

MESSAGE               LOGGING IS ENABLED, CAN NOT CLEAR LOGID

CAUSE                 The logid cannot be changed while logging is in
                      process in order to ensure validity of recovery and
                      logging.

ACTION                Change the logid after the recovery process has
                      completed.

---------------------------------------------------------------

MESSAGE               LOG PERIOD DOES NOT EQUAL ONE (1)

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               MAINTENANCE WORD CANNOT BE CHANGED UNTIL RECOVERY
                      HAS COMPLETED

CAUSE                 Changing maintenance word was attempted when
                      recovery was enabled.

ACTION                After the recovery process has completed use the
                      DBUTIL >>SET command to change the maintenance
                      word.

---------------------------------------------------------------

MESSAGE               MAINTENANCE WORD REQUIRED

CAUSE                 The user invoking the utility is not the creator of
                      the referenced database and has not supplied a
                      maintenance word.

ACTION                If DBUTIL, reenter the command with the maintenance
                      word.  Otherwise correct the error or press return
                      to terminate the program.

---------------------------------------------------------------

MESSAGE               MAINTENANCE WORD TOO LONG

CAUSE                 The specified maintenance word has more than eight
                      characters.

ACTION                Reenter the command with the correct maintenance
                      word.

---------------------------------------------------------------

MESSAGE               MAXIMUM ERROR COUNT HAS BEEN EXCEEDED

CAUSE                 DBRecov keeps track of all the errors that were
                      encountered.  If the number goes past a certain
                      threshold (default is 0, but can be configured up
                      to a maximum of 3000), DBRecov will abort.

ACTION                Correct the problems causing the errors.  If the
                      user specifies an error count, this count could
                      also be increased.

---------------------------------------------------------------

MESSAGE               MAXIMUM WARNING COUNT HAS BEEN EXCEEDED

CAUSE                 DBRecov keeps track of all the warnings that were
                      encountered.  If the number goes past a certain
                      threshold, DBRecov will abort.

ACTION                If the user specifies a warning count, this count
                      could be increased.

---------------------------------------------------------------

MESSAGE               MISSING!!

CAUSE                 The key word FILE is not found in the first record;
                      or the keyword DSLINE is not found in the second
                      record; or the keyword HELLO is not found in any of
                      the remaining records.

ACTION                Use the EDITOR to modify the record in the
                      database-access file that returned the error
                      message.

---------------------------------------------------------------

MESSAGE               MISSING DBNAME1

CAUSE                 An equal sign (=), semicolon (;), or end of line
                      followed the keyword FILE.

ACTION                Use the EDITOR to change the FILE command.

---------------------------------------------------------------

MESSAGE               MISSING DBNAME2

CAUSE                 dbname1= followed by a semicolon (;) or end of
                      line.

ACTION                Use EDITOR to change the FILE command.

---------------------------------------------------------------

MESSAGE               MISSING DSDEVICE

CAUSE                 DEV= was followed by a semicolon (;), #, or the
                      rest of the record was blank.

ACTION                Use the EDITOR to change the FILE command.

---------------------------------------------------------------

MESSAGE               MISSING LOCAL PART

CAUSE                 No characters preceded the =HELLO.

ACTION                Use the EDITOR to change the HELLO command.

---------------------------------------------------------------

MESSAGE               MISSING REMOTE PART

CAUSE                 The remote-ID-sequence of the database-access file
                      is missing.

ACTION                Use the EDITOR to add the remote part.

---------------------------------------------------------------

MESSAGE               MISSING REMOTE PASWD

CAUSE                 HELLO was not followed by text, or was followed by
                      a semicolon (;).

ACTION                Using the EDITOR, change the HELLO command.

---------------------------------------------------------------

MESSAGE               MISSING SEMI-COLON

CAUSE                 DEV= was not preceded by a semicolon (;)

ACTION                Use the EDITOR to change the FILE command.

---------------------------------------------------------------

MESSAGE               MISSING # SIGN

CAUSE                 dsdevice was not followed by a #.

ACTION                Use the EDITOR to change the FILE command.

---------------------------------------------------------------

MESSAGE               MORE THAN ONE (1) LOG FILE HEADER RECORD IS FOUND

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               MULTIPLE LOG IDENTIFIERS NOT ALLOWED

CAUSE                 You tried to simultaneously recover databases that
                      logged to different log files.

ACTION                Run DBRECOV once for each log file.

---------------------------------------------------------------

MESSAGE               NEGATIVE CURRENT RECORD NUMBER IN BACKSPACE REQUEST

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               NEGATIVE NUMBER OF BACKSPACES REQUESTED

CAUSE                 Internal error.

ACTION                Contact your system manager.

---------------------------------------------------------------

MESSAGE               NLS RELATED ERROR

CAUSE                 An error was returned by NLS/3000 on a DBOPEN on
                      the database.

ACTION                Notify the system manager.

---------------------------------------------------------------