201 MESSAGE An error occurred in the file name from tape.
CAUSE Incorrect file name read from tape.
ACTION Clean tape drive and retry. Clean tape drive and
remake tape. Determine cause of incorrect file
name on tape and correct.
---------------------------------------------------------------
202 MESSAGE The procedure failed to initialize the file
system directory on INSTALL.
CAUSE Error status returned from DRINIT file system
initialize directory.
ACTION Determine cause of error from DRINIT and correct.
---------------------------------------------------------------
203 MESSAGE An internal file number error occurred upon
trying to get the disk address of a boot file.
CAUSE File number error while getting disk address.
(Internal error.)
ACTION Call your Hewlett-Packard Representative.
---------------------------------------------------------------
204 MESSAGE An error occurred from file system FFILEINFO
getting the disk address of a boot file.
CAUSE Error returned from FFILEINFO.
ACTION Determine cause of error from FFILEINFO and
correct.
---------------------------------------------------------------
205 MESSAGE An error occurred from file system
LM_GET_1ST_EXTENT_INFO getting a disk address of a
boot file.
CAUSE Error returned from LM_GET_1ST_EXTENT_INFO
ACTION Determine cause of error from LM_GET_1ST_EXTENT_INFO
and correct.
---------------------------------------------------------------
206 MESSAGE An error occurred from I/O system reading the
label for a name file from tape for RENDEZVOUSIO.
CAUSE Error returned by RENDEZVOUSIO reading MPEXLDIR
file label.
ACTION Clean tape drive and retry. Clean tape drive,
remake tape and retry. Determine cause of error
from RENDEZVOUSIO and correct.
---------------------------------------------------------------
207 MESSAGE An error occurred from I/O system reading the
label for a name file from the tape from SENDIO.
CAUSE Error returned by SENDIO reading MPEXLDIR file
label.
ACTION Determine cause of error from SENDIO and correct.
---------------------------------------------------------------
208 MESSAGE An error occurred reading the label for the name
file. Bad tape or wrong tape position; not enough
data read.
CAUSE Error in length of data reading MPEXLDIR file
label. Tape read expected 256 bytes and got less
than 200 bytes.
ACTION Clean tape drive and retry. Clean tape drive,
remake tape and retry.
---------------------------------------------------------------
209 MESSAGE An error occurred from I/O system reading the
name file from the tape from RENDEZVOUSIO.
CAUSE Error returned by RENDEZVOUSIO reading MPEXLDIR
file data.
ACTION Clean tape drive and retry. Clean tape drive,
remake tape and retry. Determine cause of error
from RENDEZVOUSIO and correct.
---------------------------------------------------------------
210 MESSAGE An error occurred from I/O system reading the
name file from the tape from SENDIO.
CAUSE Error returned by SENDIO reading MPEXLDIR file
data.
ACTION Determine cause of error from SENDIO and correct.
---------------------------------------------------------------
211 MESSAGE An error occurred reading the name file from the
tape; bad tape or wrong tape position; not enough
data read.
CAUSE Error in length of data reading MPEXLDIR file data.
Tape read expected at least 80 bytes and got less
than 80 bytes.
ACTION Clean tape drive and retry. Clean tape drive,
remake tape and retry.
---------------------------------------------------------------
212 MESSAGE An error occurred from HPFOPEN to create the name
file.
CAUSE Error from HPFOPEN for MPEXLDIR file.
ACTION Determine cause of error from HPFOPEN and correct.
---------------------------------------------------------------
213 MESSAGE Error from FWRITE on writing name file.
CAUSE Error from FWRITE for MPEXLDIR file.
ACTION Determine cause of error from FWRITE and correct.
---------------------------------------------------------------
214 MESSAGE An error occurred from FCLOSE on the name file.
CAUSE Error from FCLOSE for MPEXLDIR file.
ACTION Determine cause of error from FCLOSE and correct.
---------------------------------------------------------------
215 MESSAGE A failure occurred from INIT_BOOTCMD_AREA.
CAUSE Error from INIT_BOOTCMD_AREA.
ACTION Determine cause of error from INIT_BOOTCMD_AREA and
correct.
---------------------------------------------------------------
216 MESSAGE A failure occurred from SAVE_BOOTCMD_TO_DISK.
CAUSE Error from SAVE_BOOTCMD_TO_DISK.
ACTION Determine cause of error from SAVE_BOOTCMD_TO_DISK
and correct.
---------------------------------------------------------------
217 MESSAGE A failure occurred from COMPUTE_FREE_ADDRESS.
CAUSE Error from COMPUTE_FREE_ADDRESS.
ACTION Determine cause of error from COMPUTE_FREE_ADDRESS
and correct.
---------------------------------------------------------------
218 MESSAGE This is an invalid free space map address from
COMPUTE_FREE_ADDRESS; conditional debug compile
option.
CAUSE Incorrect free space bit map address from
COMPUTE_FREE_ADDRESS. Debug code not released.
ACTION Call your Hewlett-Packard Representative.
---------------------------------------------------------------
219 MESSAGE A failure occurred from SM_CREATE_HASH_TBL.
CAUSE Error from SM_CREATE_HASH_TBL. Internal storage
management routine.
ACTION Determine cause of error from SM_CREATE_HASH_TBL
and correct.
---------------------------------------------------------------
220 MESSAGE A failure occurred from INSTALL_VOLUME_MGT.
CAUSE Error from INSTALL_VOLUME_MGT while initializing a
volume.
ACTION Determine cause of error from INSTALL_VOLUME_MGT
and correct.
---------------------------------------------------------------
221 MESSAGE A failure occurred from local routine LOAD_POST
writing to sector 0,1 of disk.
CAUSE Error from LOAD_POST writing to sector zero and one
of LDEV 1.
ACTION Determine cause of error from LOAD_POST and
correct.
---------------------------------------------------------------
222 MESSAGE A failure occurred from local routine LOAD_POST
writing to sector 0,1 of disk.
CAUSE Error from LOAD_POST writing to sector zero and one
of LDEV 1.
ACTION Determine cause of error from LOAD_POST and
correct.
---------------------------------------------------------------
223 MESSAGE A failure occurred from file system
FS_INITIALIZE_FILE_SYSTEM.
CAUSE Error from FS_INITIALIZE_FILE_SYSTEM.
ACTION Determine cause of error from
FS_INITIALIZE_FILE_SYSTEM and correct.
---------------------------------------------------------------
224 MESSAGE A failure occurred from file system FS_PROC_INIT.
CAUSE Error from FS_PROC_INIT, file system initialize
routine.
ACTION Determine cause of error from FS_PROC_INIT and
correct.
---------------------------------------------------------------
225 MESSAGE A failure occurred from file system directory
FAKE_LOGON.
CAUSE Error from FAKE_LOGON, file system directory
routine.
ACTION Determine cause of error from FAKE_LOGON and
correct.
---------------------------------------------------------------
226 MESSAGE A failure occurred from file system
FS_TDIRC_INIT.
CAUSE Error from FS_TDIRC_INIT, file system routine.
ACTION Determine cause of error from FS_TDIRC_INIT and
correct.
---------------------------------------------------------------
227 MESSAGE A failure occurred from local routine LOAD_POST
writing to sector 0,1 of disk.
CAUSE Error from LOAD_POST writing to sector zero and one
of LDEV 1.
ACTION Determine cause of error from LOAD_POST and
correct.
---------------------------------------------------------------
228 MESSAGE A fatal option error occurred (file name wrong);
INSTALL renamed UPDATE.
CAUSE A copy of the PME INSTALL has been given control
from the option routine with the indication that
the command used to call the PME was not INSTALL.
Probably was UPDATE. Probably a copy of INSTALL was
renamed UPDATE.
ACTION Use a correct copy of INSTALL.
---------------------------------------------------------------
229 MESSAGE Disk sparing failed on LDEV 1.
CAUSE Error returned from disk sparing of LDEV 1.
ACTION Determine cause of error from sparing and correct.
---------------------------------------------------------------
230 MESSAGE REBOOT_CPU returned control.
CAUSE The routine REBOOT_CPU has returned control to the
caller. The CPU was probably not rebooted.
ACTION Determine why control was returned from REBOOT_CPU
and correct. Reboot the CPU and continue.
---------------------------------------------------------------
231 MESSAGE Hard loop failed, probably due to compiler or
hardware error, or START/NO START error.
CAUSE The compiler generated loop to stop the CPU on a
nostart option has exited. Generated code or
hardware error.
ACTION Determine why the code exited and correct. Reboot
the CPU and continue.
---------------------------------------------------------------
232 MESSAGE An error occurred upon getting the size of the
disk.
CAUSE Error from GET_HPE_DISC_SIZE_PAGE. Internal routine
to compute the number of pages on the disk.
ACTION Determine cause of error from GET_HPE_DISC_SIZE_PAGE
and correct.
---------------------------------------------------------------
233 MESSAGE An error occurred from SM_CREATE_HASH_TBL.
CAUSE Error from SM_CREATE_HASH_TBL, storage management
routine.
ACTION Determine cause of error from SM_CREATE_HASH_TBL
and correct.
---------------------------------------------------------------
234 MESSAGE An error occurred from START_VOLUME_MGT.
CAUSE Error from START_VOLUME_MGT, volume management
routine.
ACTION Determine cause of error from START_VOLUME_MGT and
correct.
---------------------------------------------------------------
235 MESSAGE An error occurred from file system
FS_INITIALIZE_FILE_SYSTEM.
CAUSE Error FS_INITIALIZE_FILE_SYSTEM.
ACTION Determine cause of error from
FS_INITIALIZE_FILE_SYSTEM and correct.
---------------------------------------------------------------
236 MESSAGE An error occurred from file system FS_PROC_INIT.
CAUSE Error from FS_PROC_INIT, file system routine.
ACTION Determine cause of error from FS_PROC_INIT and
correct.
---------------------------------------------------------------
237 MESSAGE An error occurred from file system directory
FAKE_LOGON.
CAUSE Error from FAKE_LOGON, file system directory logon.
ACTION Determine cause of error from FAKE_LOGON and
correct.
---------------------------------------------------------------
238 MESSAGE An error occurred from file system FS_TDIRC_INIT.
CAUSE Error from FS_TDIRC_INIT, file system routine.
ACTION Determine cause of error from FS_TDIRC_INIT and
correct.
---------------------------------------------------------------
239 MESSAGE This is a fatal option error (filename wrong);
UPDATE renamed INSTALL.
CAUSE A copy of the PME UPDATE has been given control
from the option routine with the indication that
the command used to call the PME was not UPDATE.
Probably was INSTALL. Probably a copy of UPDATE was
renamed INSTALL.
ACTION Use a correct copy of UPDATE.
---------------------------------------------------------------
240 MESSAGE Disk sparing failed on LDEV 1.
CAUSE Error returned from disk sparing of LDEV 1.
ACTION Determine cause of error from sparing and correct.
---------------------------------------------------------------
241 MESSAGE REBOOT_CPU returned control.
CAUSE The routine REBOOT_CPU has returned control to the
caller. The CPU was probably not rebooted.
ACTION Determine why control was returned from REBOOT_CPU
and correct. Reboot the CPU and continue.
---------------------------------------------------------------
242 MESSAGE Hard loop failed, probably due to compiler or
hardware error, or START/NO START option error.
CAUSE The compiler generated loop to stop the CPU on a
nostart option has exited. Generated code or
hardware error.
ACTION Determine why the code exited and correct. Reboot
the CPU and continue.
---------------------------------------------------------------
243 MESSAGE Failure from SAVE_BOOT_CMD_TO_DISC.
CAUSE Error from SAVE_BOOT_CMD_TO_DISC.
ACTION Determine cause of error from SAVE_BOOT_CMD_TO_DISC
and correct.
---------------------------------------------------------------
244 MESSAGE An error was returned by CONFIGURE_DEVICE
configuring the tape drive.
CAUSE Error from CONFIGURE_DEVICE for tape control.
ACTION Determine cause of error from CONFIGURE_DEVICE and
correct.
---------------------------------------------------------------
245 MESSAGE The procedure found a second IPL on tape; bad
tape.
CAUSE Found second IPL file on the tape. Invalid tape
format.
ACTION Determine cause of the second IPL on the tape and
correct. Remake the tape and redo the UPDATE or
INSTALL.
---------------------------------------------------------------
246 MESSAGE An error was returned by ADD_DUMP_FILE.
CAUSE Error returned from ADD_DUMP_FILE. Internal routine
to add the dump file to the disk and the LIF
directory.
ACTION Determine cause of error from ADD_DUMP_FILE and
correct.
---------------------------------------------------------------
247 MESSAGE An error was received from LOAD_POST writing
label sector 0,1 to LDEV 1.
CAUSE Error from LOAD_POST writing to sector zero and one
of LDEV 1.
ACTION Determine cause of error from LOAD_POST and
correct.
---------------------------------------------------------------
248 MESSAGE No IPL from the tape; disk will not boot.
CAUSE No IPL file was found on the tape. Invalid tape
format.
ACTION Determine the cause of missing IPL file and
correct. Remake the tape and redo the UPDATE or
INSTALL.
---------------------------------------------------------------
249 MESSAGE No NL.PUB.SYS from the tape; disk will not start.
CAUSE No NL.PUB.SYS file was found on the tape. Invalid
tape format. File is identified by start number in
tape file header.
ACTION Determine the cause of missing NL.PUB.SYS file and
correct. Remake the tape and redo the UPDATE or
INSTALL.
---------------------------------------------------------------
250 MESSAGE An error was received from CREATE_OBJECT for
global area.
CAUSE Error returned from CREATE_OBJECT for global area.
ACTION Determine cause of error from CREATE_OBJECT and
correct.
---------------------------------------------------------------
251 MESSAGE An error was received from CREATE_OBJECT for page
1 buffer.
CAUSE Error returned from CREATE_OBJECT for page 1
buffer.
ACTION Determine cause of error from CREATE_OBJECT and
correct.
---------------------------------------------------------------
253 MESSAGE Bad sector table index error.
CAUSE An internal error occurred in the disk sparing
routine change sector state. Bad sector table
index error.
ACTION Retry the function (INSTALL or UPDATE or START or
mount volume). Write over sector zero to bypass
sparing on this volume and initialize it again.
Consult a Hewlett-Packard System Engineer for help.
---------------------------------------------------------------
254 MESSAGE Error on read of TRACK TABLE from RENDEZVOUSIO.
CAUSE Error returned from RENDEZVOUSIO for sparing read
track table.
ACTION Determine cause of error from RENDEZVOUSIO and
correct.
---------------------------------------------------------------
255 MESSAGE Error on read of TRACK TABLE from SENDIO.
CAUSE Error returned from SENDIO for sparing read track
table.
ACTION Determine cause of error from SENDIO and correct.
---------------------------------------------------------------
256 MESSAGE Error on write of TRACK TABLE from RENDEZVOUSIO.
CAUSE Error returned from RENDEZVOUSIO for sparing write
track table.
ACTION Determine cause of error from RENDEZVOUSIO and
correct.
---------------------------------------------------------------
257 MESSAGE Error on write of TRACK TABLE from SENDIO.
CAUSE Error returned from SENDIO for sparing write track
table.
ACTION Determine cause of error from SENDIO and correct.
---------------------------------------------------------------
258 MESSAGE An error was received from SENDIO reading bad
sector.
CAUSE Error returned from SENDIO for sparing read sector
save sector.
ACTION Determine cause of error from SENDIO and correct.
---------------------------------------------------------------
259 MESSAGE An error was received from SENDIO writing sector.
CAUSE Error returned from SENDIO for sparing write sector
save sector.
ACTION Determine cause of error from SENDIO and correct.
---------------------------------------------------------------
MPE/iX 5.0 Documentation