Ch 57. Measurement Interface [ MPE/iX Error Messages Manual Volume III ] MPE/iX 5.0 Documentation
MPE/iX Error Messages Manual Volume III
Chapter 57 Measurement Interface
(Subsystem 133)
--------------------------------------------------------------
---------------------------------------------------------------
5 MESSAGE The PID has not been created.
CAUSE The specific process no longer exists in the
system. The process has been specified by the
Measurement Interface (MI) user through the
SUBCLASS_ARRAY parameter in the procedure
ENABLE_MEASUREMENTS.
ACTION Retry with the correct process ID.
---------------------------------------------------------------
10 MESSAGE The group PARM is greater than MAX_GROUP_IN_CLASS
for requested class.
CAUSE The user of procedures which require a group value
entered an index value for the group which is
outside the range for groups within a performance
class.
ACTION Remove faulty value and try again.
---------------------------------------------------------------
15 MESSAGE Too many user or program names given in an
ENABLE_MEASUREMENT call; ENABLE_MEASUREMENTS does
continue, however.
CAUSE The user of the ENABLE_MEASUREMENT procedure has
requested more than 10 program names and/or 10 user
names.
ACTION Reduce the number of names to 10 (10 programs
and/or 10 user names) and try again.
---------------------------------------------------------------
25 MESSAGE The total subclasses were zero; condition not
acceptable.
CAUSE A negative or zero value for the parameter for
TOT_SUBCLASSER for ENABLE_MEASUREMENT and/or
DISABLE_MEASUREMENT procedures.
ACTION Correct the value and retry.
---------------------------------------------------------------
35 MESSAGE The measurement interface PID list is full.
CAUSE The user of ENABLE_MEASUREMENT has requested more
than 2700 processes to monitor.
ACTION Reduce the number of processes requested and try
again.
---------------------------------------------------------------
50 MESSAGE The user buffer is not large enough to hold all
requested counters.
CAUSE The user of GET_MEASUREMENTS has passed a buffer to
receive performance data which is too small.
ACTION Increase buffer size and try again.
---------------------------------------------------------------
65 MESSAGE The counter table has no more entries, so all
groups requested got enabled.
CAUSE Major problem with the MEASUREMENT INTERFACE data
structure whereby there was a problem getting
enough memory to create the counter array.
ACTION Scale back on the number of items being measured or
expand memory.
---------------------------------------------------------------
70 MESSAGE The requested class has an index value less than
zero or greater than the current total number of
classes.
CAUSE The requested class in ENABLE_MEASUREMENTS,
GET_MEASUREMENTS, and/or DISABLE_MEASUREMENTS is
not within the range of 1 to 3.
ACTION Correct the class value and try again.
---------------------------------------------------------------
90 MESSAGE A new subclass is requested, but the LOOKUP TABLE
is full.
CAUSE A user has specified more LDEVs than the IO
LOOKUP TABLE can accommodate in the call to
ENABLE_MEASUREMENTS.
ACTION Be more selective on the number of I/O devices.
Adjust the number of LDEVs and try again. See
limits in the MPE XL Measurement Interface User's
Guide.
---------------------------------------------------------------
100 MESSAGE ENABLE of measurement subclass failed.
CAUSE A user has tried to enable performance measurements
through the procedure ENABLE_MEASUREMENTS, but the
number of MI users exceeds the limit of 25.
ACTION Wait until an MI user quits and retry.
---------------------------------------------------------------
110 MESSAGE No measurement ID entry in the MI_ID TABLE.
CAUSE A user has called GET_MEASUREMENTS or
DISABLE_MEASUREMENTS without first enabling
measurements through the procedure
ENABLE_MEASUREMENTS.
ACTION Check to be sure that you first call
ENABLE_MEASUREMENTS.
---------------------------------------------------------------
130 MESSAGE The current class has been ENABLED too many times
without intervening DISABLES.
CAUSE Either 1) a second enable for global class, 2) more
ID class enables than total number of device
classes or more LDEVs than exist in given device
class, or 3) a change in groups selected with new
enables for new process in process class.
ACTION Correct misunderstanding in using ENABLE
MEASUREMENTS. See the MPE XL Measurement Interface
User's Guide for more information on using the
procedure ENABLE_MEASUREMENTS.
---------------------------------------------------------------
140 MESSAGE The number of counters do not match the known
number of object classes.
CAUSE User called CONVERT_TO_STD_OBJCL procedure with
group whose group header shows a number of counters
to be not 10, 33, or 501.
ACTION Check to be sure group is an object class group.
Modify input and try again.
---------------------------------------------------------------
150 MESSAGE The group index does not belong to an object
class group.
CAUSE User called CONVERT_TO_STD_OBJCL procedure with a
group that is not recognized as an object class
group for the particular class.
ACTION Check to be sure the group is an object class
group. Modify input and try again.
---------------------------------------------------------------
160 MESSAGE LDEVS in the array are not all of the same device
type.
CAUSE User called ENABLE_MEASUREMENT with an array of
LDEVs that are not of the same device class, or
user called DISABLE_MEASUREMENTS with an array of
LDEVs that are not of the same device class.
ACTION Correct LDEVs in the array to be of the same device
class and retry.
---------------------------------------------------------------
170 MESSAGE Failed to obtain lock for the MEAS_KSO_TABLE.
CAUSE Major problem with MEASUREMENT INTERFACE data
structure or control block lock code of the
operating system.
ACTION Call your Hewlett-Packard Representative.
---------------------------------------------------------------
180 MESSAGE Failed to obtain lock for the PROCESS LOOKUP
SUBCLS TABLE.
CAUSE Major problem with MEASUREMENT INTERFACE data
structure, or control block lock code of the
operating system.
ACTION Call your Hewlett-Packard Representative.
---------------------------------------------------------------
190 MESSAGE Failed to obtain lock for the NAME POINTER LIST
TABLE.
CAUSE Major problem with MEASUREMENT INTERFACE data
structure, or TABLE MANAGEMENT control block lock
code of the operating system.
ACTION Call your Hewlett-Packard Representative.
---------------------------------------------------------------
200 MESSAGE Failed to obtain lock for the MI_ID TABLE.
CAUSE Major problem with MEASUREMENT INTERFACE data
structure, or Table Management control block lock
code of the operating system.
ACTION Call your Hewlett-Packard Representative.
---------------------------------------------------------------
210 MESSAGE Failed to obtain lock for the USER_LIST TABLE.
CAUSE Major problem with MEASUREMENT INTERFACE data
structure or TABLE MANAGEMENT control block lock
code of the operating system.
ACTION Call your Hewlett-Packard Representative.
---------------------------------------------------------------
220 MESSAGE Failed to obtain lock for PROG_LIST TABLE.
CAUSE Major problem with MEASUREMENT INTERFACE data
structure or TABLE MANAGEMENT control block lock
code of the operating system.
ACTION Call your Hewlett-Packard Representative.
---------------------------------------------------------------
MPE/iX 5.0 Documentation