HP 3000 Manuals

Ch 45. CM Support Routines [ MPE/iX Error Messages Manual Volume III ] MPE/iX 5.0 Documentation


MPE/iX Error Messages Manual Volume III

Chapter 45  CM Support Routines 

(Subsystem 154) 

--------------------------------------------------------------

---------------------------------------------------------------

10           MESSAGE    The code segment number is invalid.

           CAUSE      The caller passed in a code segment which is
                      invalid for the process whose PIN was passed in, or
                      the code segment is unassigned.

           ACTION     None.

---------------------------------------------------------------

30           MESSAGE    The data segment number is invalid.

           CAUSE      The caller passed in an invalid or an unassigned
                      data segment number.

           ACTION     None.

---------------------------------------------------------------

60           MESSAGE    FREEZE returned a bad status.

           CAUSE      The memory manager failed to freeze a compatibility
                      mode code or data segment into memory.

           ACTION     Examine the process error stack to determine what
                      may have caused the problem.

---------------------------------------------------------------

65           MESSAGE    UNFREEZE returned a bad status.

           CAUSE      The memory manager failed to unfreeze a
                      compatibility mode code or data segment into
                      memory.

           ACTION     Examine the process error stack to determine what
                      may have caused the problem.

---------------------------------------------------------------

160          MESSAGE    SWITCH_TO_CM returned a bad status.

           CAUSE      Corruption of an operating system data structure or
                      operating system code caused SWITCH_TO_CM to fail.

           ACTION     Examine the process error stack to determine what
                      may have caused the problem.

---------------------------------------------------------------

301          MESSAGE    The logical device parameter is not a real
                      device.

           CAUSE      An attempt was made to place a non-existent device
                      or a spooler virtual device into diagnostic mode.

           ACTION     None.

---------------------------------------------------------------

302          MESSAGE    The device is currently not in diagnostic mode.

           CAUSE      An attempt was made to remove a device not owned by
                      the diagnostic system from the diagnostic mode.

           ACTION     None.

---------------------------------------------------------------

304          MESSAGE    The device is already in diagnostic mode.

           CAUSE      An attempt was made to place a device which was
                      already owned by the diagnostic system into the
                      diagnostic mode.

           ACTION     None.

---------------------------------------------------------------

305          MESSAGE    The device is currently in use.

           CAUSE      An attempt was made to place a device currently
                      being accessed by a user into the diagnostic mode.

           ACTION     Try again once the user is no longer accessing the
                      device.  The SHOWDEV command can be used to
                      determine the current owner.

---------------------------------------------------------------

309          MESSAGE    The spooler for the device could not be stopped.

           CAUSE      While attempting to place a device into the
                      diagnostic mode, the system could not stop the
                      spooler active on the device.

           ACTION     Use the STOPSPOOL command to stop the spooler.  If
                      sucessful, attemp the diagnostic again.

---------------------------------------------------------------

311          MESSAGE    The spooler for the device could not be
                      restarted.

           CAUSE      While removing the device from the diagnostic mode,
                      the system could not restart a spooler for the
                      device.

           ACTION     If desired, use the STARTSPOOL command on the
                      console to start a spooler for the device.

---------------------------------------------------------------

312          MESSAGE    The spooler for the device could not be
                      suspended.

           CAUSE      While attempting to place a device into diagnostic
                      mode, the system could not suspend the currently
                      active spoolfile.

           ACTION     Try using the SUSPENDSPOOL command on the console
                      to suspend the currently active spoolfile.

---------------------------------------------------------------

320          MESSAGE    The logical console cannot be placed in
                      diagnostic mode.

           CAUSE      An attempt was made to place the logical console
                      into diagnostic mode.

           ACTION     Move the logical console to another terminal using
                      the CONSOLE command.

---------------------------------------------------------------

321          MESSAGE    Disks cannot be placed in diagnostic mode.

           CAUSE      An attempt was made to place a disk into diagnostic
                      mode.

           ACTION     None.

---------------------------------------------------------------

2550         MESSAGE    GETSIR returned a bad status to the fast switch
                      stub.

           CAUSE      Corruption of an operating system data structure or
                      operating system code caused GETSIR to fail.

           ACTION     Perform a system dump.  Reboot the system using
                      START.

---------------------------------------------------------------

2551         MESSAGE    RELSIR returned a bad status to the fast switch
                      stub.

           CAUSE      Corruption of an operating system data structure or
                      operating system code caused RELSIR to fail.

           ACTION     Perform a system dump.  Reboot the system using
                      START.

---------------------------------------------------------------



MPE/iX 5.0 Documentation