Job Control Word Intrinsics
The following intrinsics are used to manipulate JCWs. Note that the
first intrinsic affects only the predefined Job Control Word called JCW;
the rest can be used with any JCW in the session variable table.
SETJCW
The SETJCW intrinsic is used to set the bits in the predefined Job
Control Word JCW. A SETJCW intrinsic call could be:
SETJCW(WORD);
where WORD is a 16-bit logical value whose bits are set by you. If you
set bit (0:1)=1, the system displays the following message when your
program terminates, either normally or due to an error:
PROGRAM TERMINATED IN AN ERROR STATE (CIERR 976)
Bits (1:15) may be set to any pattern.
NOTE In batch mode, the job is terminated unless the :CONTINUE command
is used. If you have a JCW of exactly %140000 (bits (0:2) only),
the "CIERR 976" message is replaced by "CIERR 989, PROGRAM ABORTED
PER USER REQUEST" . Refer to the MPE XL Commands Reference Manual
(32650-90003) for a discussion of :CONTINUE.
The predefined Job Control Word JCW can be read by a process with the
GETJCW intrinsic. The form of the GETJCW intrinsic call is:
JCW:=GETJCW
The Job Control Word is returned to JCW.
For example, consider a job where two processes in the same process tree
pass information to each other through JCW. In one process, you transmit
the contents of the word PROCLNK to JCW. Process A sets JCW to PROCLNK as
follows:
SETJCW(PROCLNK);
When process B is executed, it obtains the value of JCW through the
GETJCW intrinsic. In this case, the contents of JCW are returned to the
word STORELNK.
STORELNK:=GETJCW;
PUTJCW
The PUTJCW intrinsic is used to establish a user-defined JCW, or to
change the value of an existing JCW. This intrinsic scans the variable
table for the JCW name. The name of a user-defined JCW must be
alphanumeric, must start with a letter, and must be between 1 and 255
characters long. If the JCW name is found, the value of JCW is updated
to the value passed by PUTJCW. If not found, the JCW name is added to the
table and assigned the value passed with the name. For example, the
intrinsic call:
PUTJCW(JCWNAME,JCWVALUE,STATUS);
searches the variable table for a name that matches the name contained in
JCWNAME (a character array). If the name exists, its value is updated to
the value contained in JCWVALUE. If the name is not found, the name is
added to the table and assigned the value contained in JCWVALUE.
The STATUS parameter of PUTJCW indicates the status of the intrinsic call
and returns an integer value to indicate this status, as follows:
0 Successful execution.
1 Error. JCWNAME is longer than 255 characters.
2 Error. JCWNAME does not start with a letter.
3 Error. The variable table is out of space.
4 Error. Attempted to assign a value to an MPE XL-defined
JCW value mnemonic (OK, WARN, FATAL, or SYSTEM).
5 Error. Cannot assign a value to a system-reserved JCW
(for example, PUTJCW(HPMONTH) is illegal).
6 Warning. A standard variable has been reclassified as a
JCW. (This happens when a variable set with SETVAR has
its value altered with PUTJCW or SETJCW.)
7 Error. Cannot reclassify predefined standard variables
as JCWs (for example, PUTJCW (HPPROMPT) is illegal).
FINDJCW
The FINDJCW intrinsic is used to scan the variable table for a JCW and
return its value. Thus, the intrinsic call:
FINDJCW(JCWNAME,JCWVALUE,STATUS);
searches the variable table for a JCW of the same name as that contained
in JCWNAME. If found, its current value is returned in JCWVALUE. If not
found, an error is returned in STATUS, and JCWVALUE is returned
unchanged.
The STATUS parameter of FINDJCW indicates the status of the intrinsic
call and returns an integer value indicating this status as follows:
0 Successful execution.
1 Error. JCWNAME is longer than 255 characters.
2 Error. JCWNAME does not start with a letter.
3 Error. The JCW named in JCWNAME does not exist.
For more information and full syntax descriptions for the above
intrinsics, refer to the MPE XL Intrinsics Reference Manual
(32650-90028).