SHOW Command 

SHOW displays the values of all the DEFINE and VPLUS parameters.  Default
values are displayed for those parameters that were not specifically
assigned a value.  If a parameter without an existing default value
(e.g., FORMSFILE parameter for the VPLUS command) has not been
initialized, asterisks (***) are displayed.

Syntax 

     SHOW  [.]

Parameters:  None

Example: 

     > SHOW 

     DEFINE command parameters:
     DICTIONARY          = SYSDIC
     SCOPE               = DA
     DOMAIN              = MARSHA
     VERSION             = V1
     OPEN-MODE           = EXCLUSIVE-UPDATE
     NAME-MODE           = EXTERNAL

     VPLUS command parameters:
     FORMSFILE           = INVENTORY
     SENSITIVITY         = READ
     CHAR                = OFF
     HYPHEN              = OFF
     CHECK-ELEM-TYPE     = ON
     COMPATIBILITY-LEVEL = VPLUS-COMPATIBILITY
     OPTION              = PROMPT
     QUIET