HP 3000 Manuals

SDGetEnt [ HP System Dictionary XL Intrinsics ] MPE/iX 5.0 Documentation


HP System Dictionary XL Intrinsics

SDGetEnt 

Retrieves an entity's attributes.

Syntax 

     SDGetEnt (Dcb,EntityType,Entity,AttributeList, 
                AttributeValues,CommonEntity,Status)

Parameters 

Dcb                       Required input; type = DcbType 
                          This parameter passes information about the
                          dictionary to this intrinsic.  It is
                          initialized by the SDOpen intrinsic.

EntityType                Required input; type = NameOrNumberType 
                          This parameter specifies the entity type of the
                          entity whose attributes are to be retrieved.

Entity                    Required input; type = NameOrNumberType 
                          This parameter specifies the entity whose
                          attributes are to be retrieved.

AttributeList             Required input; type = AttributeListType 
                          This parameter specifies the attributes whose
                          values are to be retrieved.  This list will be
                          considered empty if the first character is the
                          list terminator ( ; ) or if the number of
                          internal numbers in the parameter is zero.

AttributeValues           Output; type = AttributeValuesType 
                          This parameter contains the values of the
                          attributes that are retrieved.

CommonEntity              Output; type = NameType 
                          This parameter returns the name of the common
                          domain entity to which this local domain entity
                          is linked.  If it is not linked to a common
                          domain entity, this parameter returns ASCII
                          blanks.

Status                    Output; type = StatusType 
                          This parameter contains information indicating
                          the success or failure of the intrinsic call.
                          This information is detailed in Table Table
                          3-1, located in Chapter 3 of this manual.

                          If this intrinsic is successful, the Status 
                          parameter contains the following information,
                          in addition to the description contained in
                          Table Table 3-1.

----------------------------------------------------------------------
|              |                                                     |
|    Bytes     |                       Contain                       |
|              |                                                     |
----------------------------------------------------------------------
|              |                                                     |
| 17 - 20      | Internal entity number                              |
|              |                                                     |
----------------------------------------------------------------------

Discussion 

The following restrictions apply when using this intrinsic:

   1.  Open mode--The dictionary must be opened in Shared Read mode,
       Shared Read-Only mode, Shared Update mode, or Exclusive Update 
       mode.

   2.  Security--The current scope must be either the Dictionary
       Administrator scope or a scope with Read access to the entity.


MPE/iX 5.0 Documentation