1325     MESSAGE      The !  keyword is ignored in customization mode (SDWARN 1325) 

         CAUSE        The indicated keyword is not allowed if the open mode of the
                      dictionary is going to be CUSTOMIZATION.

         ACTION       Do nothing as the clause is ignored.  The next time the
                      dictionary is open in CUSTOMIZATION mode, do not specify this
                      keyword.

--------------------------------------------------------------------------------------

1326     MESSAGE      Both VERSION and STATUS were specified.  STATUS is ignored 
                      (SDWARN 1326) 

         CAUSE        Both the VERSION and STATUS keyword cannot be specified in the
                      same command.  Either VERSION for a specific version or STATUS
                      for the last version of the given status should be used.

         ACTION       Do nothing as the version will be used and the status ignored.
                      The next time the dictionary is opened, specify either a
                      specific version (VERSION) or a specific status (STATUS) but not
                      both.

--------------------------------------------------------------------------------------

1327     MESSAGE      Quoted passwords cannot extend to multiple lines (SDERR 1327) 

         CAUSE        If the password is entered within quotes it must be entered on a
                      single line.

         ACTION       Specify the password so that the opening and closing quotes are
                      on the same line.

--------------------------------------------------------------------------------------

1328     MESSAGE      Invalid scope password.  Remember case counts (SDWARN 1328) 

         CAUSE        An invalid password has been entered in response to the scope
                      password prompt.  Remember, System Dictionary distinguishes
                      between uppercase and lowercase characters in a scope password.

         ACTION       Specify the correct password for the scope.

--------------------------------------------------------------------------------------

1329     MESSAGE      Exceeded maximum tries for a valid scope password (SDERR 1329) 
         CAUSE        Unable to open the dictionary because a valid scope password was
                      not specified within three tries.

         ACTION       Reenter the DEFINE command and specify the correct password for
                      the scope.

--------------------------------------------------------------------------------------

1330     MESSAGE      Unexpected End-Of-File on $STDINX (SDERR 1330) 

         CAUSE        Reached the end of the file on $STDINX when trying to read the
                      scope password.

         ACTION       Refer to the associated file error and correct the indicated
                      problem.

--------------------------------------------------------------------------------------

1331     MESSAGE      Unable to turn the echo facility off (SDERR 1331) 

         CAUSE        Unable to turn the echo facility off through the FControl
                      Intrinsic when prompting for the scope password.

         ACTION       Contact the DA. (Remember to get the associated file error,
                      too.)

--------------------------------------------------------------------------------------

1332     MESSAGE      Unable to turn the echo facility on (SDERR 1332) 

         CAUSE        Unable to turn the echo facility on through the FControl
                      Intrinsic when prompting for the scope password.

         ACTION       Contact the DA. (Remember to get the associated file error,
                      too.)