IGNERR [ FCOPY Reference Manual ] MPE/iX 5.0 Documentation
FCOPY Reference Manual
IGNERR
Bypasses errors in a magnetic tape fromfile and counts ignored errors up
to a specified maximum.
Syntax
;IGNERR [=number-of-errors]
Where:
number-of-errors Is an integer specifying the maximum number of
errors to be ignored. If the number of errors
exceeds the maximum, the operation terminates.
File Attributes
The fromfile must be a magnetic tape unit with read access, and the
tofile must have write access.
Operation
You can use IGNERR only with magnetic tape fromfiles. IGNERR ignores the
following file system errors:
21 Data Parity Error
26 Transmission Error
27 I/O Timeout Error
38 Tape Parity Error
Errors other than these cause the operation to terminate.
Example
In the following example, the system ignores up to five errors while
copying the first file on the magnetic tape unit *TAPE to the disk file
FILE3. The operation terminates if FCOPY encounters a sixth error:
>FROM=*TAPE;TP=FILE3;SUBSET;IGNERR=5
MPE/iX 5.0 Documentation