Start RPRINTER at Product Startup
Toggles ACTIVE/INACTIVE. Default INACTIVE. Set to ACTIVE to allow
RPRINTER to startup when the product is started using NW START. (Also see
PSERVER Parameters).
Max Wait Packet Time
y;
This parameter specifies the maximum time in milliseconds that RPRINTER
waits to receive packets before going on to other processes. The default
is 2500 milliseconds; the range is 100 to 3200.
Status Check Time Interval
This parameter specifies the time in seconds that RPRINTER will be idle
when checking status. The default is 5 seconds; the range is 1 to 3600.
Idle Count Before Job End
This parameter specifies the maximum number of status counts that
RPRINTER waits after packets have stopped coming before deciding that the
print job has ended. Increase this count if RPRINTER is incorrectly
assuming that print jobs have ended.
This count is multiplied by the Status Check Interval to determine the
actual amount of time to wait; for example, if the Status Check Interval
is 5 seconds and this count is 2, then the printer waits 10 seconds. The
default is 2; the range is 1 to 60.
Idle Count Before Printer Status
This parameter specifies the maximum number of status counts that
RPRINTER will skip doing a status check on an idle printer.
This count is multiplied by the Status Check Interval to determine the
actual amount of time to wait; for example, if the Status Check Interval
is 5 seconds and this count is 20, then RPRINTER waits 100 seconds. The
default is 20; the range is 1 to 32000.
Error Count Before Inform
;
This parameter specifies the maximum number of times that RPRINTER should
skip displaying a second or subsequent identical error message. This is
used to prevent the scrolling of error messages that occur in rapid
succession. The default is 5; the range is 1 to 32000.
Warn Count Before Inform
This parameter specifies the maximum number of times that rprinter should
skip displaying a second or subsequent identical warning message. This
is used to prevent the scrolling of warning messages that occur in rapid
succession. The default is 5; the range is 1 to 32000.