HP 3000 Manuals

Step 8: Add Volumes [ Netware 3.11 for the HP 3000 Installing and Administering Guide ] MPE/iX 5.5 Documentation


Netware 3.11 for the HP 3000 Installing and Administering Guide

Step 8:  Add Volumes 

If you have more than one volume, you must enter the additional migrated
volumes in SCONSOLE to complete migration.  Volume SYS is automatically
added when you use the MIGRATE utility as shown in Table 5-9 .

   1.  Log into your MPE system:

       :hello manager.sys,netware

   2.  Type the command:

       :run SCONSOLE

   3.  From the Main menu, select the following options:

                                 Table 5-8.   

---------------------------------------------------------------
|  |       |                                                  |
|  | 2.    | Configuration                                    |
|  |       |                                                  |
---------------------------------------------------------------
|  |       |                                                  |
|  | 2.    | Services Configuration                           |
|  |       |                                                  |
---------------------------------------------------------------
|  |       |                                                  |
|  | 1.    | File Services Configuration                      |
|  |       |                                                  |
---------------------------------------------------------------
|  |       |                                                  |
|  | 1.    | Add a Volume                                     |
|  |       |                                                  |
---------------------------------------------------------------

   4.  Use the list of volumes that were migrated listed in the file:
       volinfo.netware.sys and enter each volume's information in
       SCONSOLE in order.  you are prompted for information as follows:

          Table 5-9.  Migration Utility 

------------------------------------------------------------------
|                    |                                           |
|     Question:      |              Type the Value:              |
|                    |                                           |
------------------------------------------------------------------
|                    |                                           |
| New Volume Name    | Enter the name on your list.              |
|                    |                                           |
------------------------------------------------------------------
|                    |                                           |
| New Name Space     | dos (Only dos is valid in this release).  |
|                    |                                           |
------------------------------------------------------------------
|                    |                                           |
| New Host Path:     | /usr/netware/new_vol (To accept the       |
|                    | default path, press <Enter>.  Otherwise,  |
|                    | enter a new host path.)                   |
|                    |                                           |
------------------------------------------------------------------
|                    |                                           |
| New NWinode File   | /usre/netware/NWControl/new_vol/inodes    |
| Path               | (Press <y> to accept the NWinode file     |
|                    | path.)                                    |
|                    |                                           |
------------------------------------------------------------------

       For more information on creating and modifying volumes, see
       Chapter 7, Advanced Configuration, and Chapter 10, SCONSOLE
       Reference for a description of the volume configuration options.

   5.  To exit SCONSOLE, enter e at the Request prompt.

   6.  Go to Step 9:  Reconfigure Printing Services.