Answer 1.  The first action executed is the Initial Action that is
specified by the HP ALLBASE/4GL administrator when the application is
defined.

Answer 2.  The  Trace Mode  function key is only available within
application testing.  To locate the key, press the  System Keys  function
key, and then the  More Keys  function key.

Answer 3.  Yes, you can move to previous fields from a required field.
However, you cannot move to any fields after the required field until the
required field is completed.

Answer 4.  Data screens and record layouts must be generated.

Answer 5.  Application titles and field specifications do not need to be
generated.

Answer 6.  *FIELDNO is an alterable communication area field.  It
contains the number of the current screen field.

Answer 7.  No, the status of the *ENTERED switch cannot be changed
programmatically.

Answer 8.  During display field processing, only Primary data movements
and Default data movements are performed.  The Primary move is always
performed, but the Default move is only performed if the screen field is
blank.