The error and warning message listed in the following four tables are
generated by the four programs that make up the MPT product.

MPTPROD Program Error Messages 

The error and warning messages listed below may result when running the
MPTPROD program.  Any of these errors may indicate some problems with the
MPTPROD program, the MPT message catalog, or the MPTPARMS parameter file.

 3         MESSAGE       UNABLE TO OPEN THE PRODUCTS FILE (MPTPARMS).

         CAUSE         The FOPEN intrinsic failed.

         ACTION        Be sure that the MPTPARMS file has been localized using the
                       appropriate file equation.   MPTPROD expects the file to be in
                       the same group in which it is executing.  For further
                       information, refer to the Migration Process Guide (30367-90007)
                       for details.  If the problem cannot be resolved, please contact
                       a Hewlett-Packard Support Representative.

 10        MESSAGE       UNABLE TO OPEN THE 'BSTORE' DATABASE

         CAUSE         The DBOPEN intrinsic failed while trying to open the 'BSTORE'
                       database.

         ACTION        Refer to the IMAGE Data Base Management System Reference Manual 
                       (32215-90003) or TurboIMAGE Data Base Management System 
                       Reference Manual (32215-90050) for details.  If the problem
                       cannot be resolved, please contact a Hewlett-Packard Support
                       Representative.

 11        MESSAGE       UNABLE TO CREATE THE PRODUCTS FILE (MPTPARMS)

         CAUSE         The FOPEN intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved from this information, please
                       contact a Hewlett-Packard Support Representative.

MPT Program Error Messages 

The error and warning messages listed below may result when running the
MPT program.  Any of these errors may indicate some problems with the MPT
program, the MPT message catalog, or the MPTPARMS parameter file.

 3         MESSAGE       UNABLE TO CREATE SON PROCESS (CREATEPROCESS ERROR
                       errornumber).

         CAUSE         The CREATEPROCESS intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, contact a Hewlett-Packard
                       Support Representative.  Include all information listed by the
                       MPT program.

 10        MESSAGE       OPEN ERROR errornumber ON SL FILE filenumber.

         CAUSE         The FOPEN intrinsic failed to open an SL file.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.

 11        MESSAGE       READ ERROR errornumber ON SL FILE filenumber.

         CAUSE         The FREAD intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.  Include all
                       information listed by the MPT program.

 12        MESSAGE       OPEN ERROR errornumber ON PROGRAM FILE filenumber.

         CAUSE         The FOPEN intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.  Include all
                       information listed by the MPT program.

          Table I-6.  (cont.) 

 13        MESSAGE       READ ERROR errornumber ON PROGRAM FILE filenumber.

         CAUSE         The FOPEN intrinsic failed to open an SL file.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.

 14        MESSAGE       OPEN ERROR errornumber ON ASCII FILE filenumber.

         CAUSE         The FOPEN intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.  Include all
                       information listed by the MPT program.

 15        MESSAGE       READ ERROR errornumber ON ASCII FILE filenumber.

         CAUSE         The FREAD intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.  Include all
                       information listed by the MPT program.

 17        MESSAGE       NO PROGRAMS WERE FOUND IN THE 'MPTPARMS' FILE.  RUNNING
                       INCOMPATIBLE PROGRAMS CAN'T BE FLAGGED IN UDCS OR STREAMS BUT
                       THE FILE SCANNING WILL CONTINUE ANYWAY.

         CAUSE         MPT reached the end of the file and failed to locate the
                       $PROGRAM section.

         ACTION        MPTPARMS is part of the MPT product and should be on the store
                       tape as MPTPARMS. Make sure the MPTPARMS file contains the
                       $PROGRAM section.  If not, restore MPTPARMS from the product
                       tape and recheck.  If the problem cannot be resolved, please
                       contact a Hewlett-Packard Support Representative.

 19        MESSAGE       NO COMMANDS WERE FOUND IN THE 'MPTPARMS' FILE.  NO UDC OR
                       STREAM FILE INCOMPATIBILITIES CAN BE FLAGGED BUT THE FILE
                       SCANNING WILL CONTINUE ANYWAY.

         CAUSE         MPT reached the end of the file and failed to locate the
                       $COMMANDS section.

         ACTION        Make sure that the $COMMANDS section of the MPTPARMS file was
                       on the original product tape.  If not, please contact a
                       Hewlett-Packard Support Representative.  If no information on
                       UDC or commands is desired, make sure that no list of commands
                       follows the $COMMANDS section.

          Table I-6.  (cont.) 

 21        MESSAGE       NO INTRINSICS WERE FOUND IN THE 'MPTPARMS' FILE.  NO PROGRAM
                       FILE INCOMPATIBILITIES CAN BE FLAGGED BUT THE FILE SCANNING
                       WILL CONTINUE ANYWAY.

         CAUSE         MPT reached the end of the file and failed to locate the
                       $INTRINSICS section.

         ACTION        Make sure the $INTRINSICS section of the MPTPARMS file was
                       included on the original product tape.  If not, please contact
                       a Hewlett-Packard Support Representative.

 28        MESSAGE       UNABLE TO FIND THE FILE CODE PARAMETERS IN THE 'MPTPARMS'
                       FILE.  THIS INFORMATION IS CRITICAL TO THE OPERATION OF THIS
                       PROGRAM.  PLEASE LOCATE THE PROPER FILE AND MAKE IT ACCESSIBLE
                       TO THIS PROGRAM.

         CAUSE         MPT reached the end of the file and failed to locate the $FCODE
                       section.

         ACTION        Make sure the $FCODE section of the MPTPARMS file was on the
                       original store tape.  If not, please contact a Hewlett-Packard
                       Support Representative.

 33        MESSAGE       UNABLE TO OPEN THE MPT PARAMETER FILE filenumber.

         CAUSE         The FOPEN intrinsic failed.

         ACTION        MPT expects the parameter file to be named MPTPARMS. Make sure
                       the MPT parameter file was installed from the product tape.  If
                       not, restore it.  If the MPT parameter file was installed, make
                       sure the appropriate file equations are set up to localize the
                       parameter file.  If the parameter file is not on the tape,
                       please contact a Hewlett-Packard Support Representative.

 42        MESSAGE       UNABLE TO OPEN OR CREATE THE 'MPTDB' DATABASE.

         CAUSE         The DBOPEN intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.

 43        MESSAGE       UNABLE TO CREATE AN EXTRA DATA SEGMENT.

         CAUSE         The GETDSEG intrinsic failed while allocating an extra data
                       segment.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.  Include all
                       information listed by the MPT program.

          Table I-6.  (cont.) 

 44        MESSAGE       UNABLE TO RELEASE EXTRA DATA SEGMENT.

         CAUSE         The FREEDSEG intrinsic failed.

         ACTION        Please contact a Hewlett-Packard Support Representative.

 45        MESSAGE       TOO MANY DATABASE ERRORS HAVE OCCURRED (> maxerrors).

         CAUSE         The maximum number of allowable database errors (10) has been
                       exceeded.  Increase the default value by setting the MAXDBERR
                       JCW.

         ACTION        Refer to the IMAGE Data Base Management System Reference Manual 
                       (32215-90003) or TurboIMAGE Data Base Management System 
                       Reference Manual (32215-90050) for information.  If the problem
                       cannot be resolved, please contact a Hewlett-Packard Support
                       Representative.  Include all information listed by the MPT
                       program.

 47        MESSAGE       ERROR OCCURRED WHILE CREATING $STDIN FILE filenumber.

         CAUSE         The FOPEN intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.

 48        MESSAGE       ERROR OCCURRED WHILE CREATING $STDLIST FILE filenumber.

         CAUSE         The FOPEN intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.

 50        MESSAGE       UNABLE TO RUN DBSCHEMA.PUB.SYS (CREATEPROCESS ERROR
                       errornumber).

         CAUSE         The CREATEPROCESS intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.

          Table I-6.  (cont.) 

 51        MESSAGE       ERROR OCCURRED WHILE READING THE $STDLIST FILE.

         CAUSE         The FREAD intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.

 52        MESSAGE       ERROR OCCURRED WHILE WRITING TO THE $STDIN FILE.

         CAUSE         The FWRITE intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.  Include all
                       information listed by the MPT program.

 53        MESSAGE       UNABLE TO RUN DBUTIL.PUB.SYS (CREATEPROCESS ERROR
                       errornumber).

         CAUSE         The CREATEPROCESS intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.  Include all
                       information listed by the MPT program.

 54        MESSAGE       UNABLE TO OPEN THE NEWLY CREATED 'MPTDB' DATABASE.

         CAUSE         The DBOPEN intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.  Include all
                       information listed by the MPT program.

 55        MESSAGE       INVALID ENTRY IN THE 'FCODE' INFORMATION (NO "=" FOLLOWING
                       number).

         CAUSE         An equal sign is missing after the file code name in the $FCODE
                       section of the MPPARMS file.

         ACTION        Be sure that entries in the $FCODE section of the MPTPARMS file
                       have the proper syntax.  Contact a Hewlett-Packard Support
                       Representative.

          Table I-6.  (cont.) 

 56        MESSAGE       INVALID ENTRY IN THE 'FCODE' INFORMATION (NO FCODE"="
                       PARAMETER).

         CAUSE         The format for one of the file codes in the $FCODE section of
                       the MPTPARMS file is invalid.

         ACTION        Check the MPTPARMS file for errors in the file code formats.
                       Make sure the $FCODE section of the MPTPARMS file consists of
                       entries in the following format:

                            PROG  = 1029
                            SL    = 1031
                                  .      .
                                  .
                            FCODE = parameter

                       Contact a Hewlett-Packard Support Representative for the proper
                       file code information.

 57        MESSAGE       IMAGE ROOT FILE HAS INVALID CONDITION CODE (nnn)

         CAUSE         The root file of a pre-TurboIMAGE database is invalid and
                       cannot be analyzed by MPT. This error occurred before reading
                       record 0 of the root file.

         ACTION        None.

 58        MESSAGE       READ ERROR ON IMAGE ROOT FILE.

         CAUSE         The FREAD intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, contact a Hewlett-Packard
                       Support Representative.  Include all information listed by the
                       MPT program.

 59        MESSAGE       ??????  ROOT FILE IS TOO LARGE FOR ANALYSIS.

         CAUSE         The size of the database is too large for MPT to handle.

         ACTION        The database cannot be analyzed by MPT. It is unusual to find a
                       root file of this size.  Please contact a Hewlett-Packard
                       Support Representative if this database must be analyzed.

          Table I-6.  (cont.) 

 60        MESSAGE       ???????  ROOT FILE IS INVALID (nnn) 

         CAUSE         This error occurs on non-TurboIMAGE databases.  MPT does not
                       recognize the IMAGE version that created this root file, or the
                       maximum root length (the number of items or number of sets) has
                       been exceeded.

         ACTION        MPT cannot analyze the database associated with this root file.
                       Please contact a Hewlett-Packard Support Representative.

 61        MESSAGE       ERROR ON MOVING DATA TO EXTRA DATA SEGMENT.

         CAUSE         The DMOVOUT intrinsic failed.  A root file could not be moved
                       into the extra data segment.

         ACTION        The database cannot be analyzed.  Please contact a
                       Hewlett-Packard Support Representative.

 62        MESSAGE       UNABLE TO CLOSE IMAGE ROOT FILE.

         CAUSE         The FCLOSE intrinsic failed.

         ACTION        Use the printed file information to determine the cause of the
                       problem.  If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.  Include all
                       information listed by the MPT program.

 63        MESSAGE       ERROR ON CALLING NM IMAGE DETAIL ROUTINE (nnn) 

         CAUSE         The PGDETAILSPACE routine failed.

         ACTION        Contact a Hewlett-Packard Support Representative.  Include all
                       information listed by the MPT program.

 64        MESSAGE       ERROR ON CALLING NM IMAGE MASTER ROUTINE (nnn) 

         CAUSE         The PGMASTERSPACE routine failed.

         ACTION        Contact a Hewlett-Packard Support Representative.  Include all
                       information listed by the MPT program.

MPTRTM Program Error Messages 

The error and warning messages listed below may result when running the
MPTRTM program.  Any of these errors may indicate some problems with the
MPTRTM program, the MPT message catalog, the MPTDB database, or the
MPTPARMS parameter file.

 2         MESSAGE       UNABLE TO OPEN THE 'MPTDB' DATABASE.

         CAUSE         The DBOPEN intrinsic failed.

         ACTION        Be sure the MPTDB has been localized properly by using the
                       appropriate file equations.  If this does not solve the
                       problem, check to see if you have the appropriate capabilities
                       to access the database.  The SM capability is required.  Check
                       to see if the database has been created.  If not, run MPT to
                       create it.  If the database is inaccessible, use the DBUTIL
                       utility program to make it accessible.  Refer to the IMAGE Data 
                       Base Management System Reference Manual (32215-90003) or
                       TurboIMAGE Data Base Management System Reference Manual 
                       (32215-90050) for details.

 8         MESSAGE       UNABLE TO COMPLETE THE LISTF COMMAND.

         CAUSE         The COMMAND intrinsic failed.

         ACTION        The file that MPT uses to scan the system logfiles is empty.
                       Please contact a Hewlett-Packard Support Representative.
                       Include all information listed by the MPTRTM program.

 9         MESSAGE       UNABLE TO OPEN THE LISTF FILE.

         CAUSE         The FOPEN intrinsic failed to open the file with the names of
                       the system log files.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.  Include all
                       information listed by the MPTRTM program.

 13        MESSAGE       UNABLE TO OPEN THE TAPE.

         CAUSE         The FOPEN intrinsic failed to open the tape drive.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.  Include all
                       information listed by the MPTRTM program.

          Table I-6.  (cont.) 

 14        MESSAGE       ATTEMPT TO ADDRESS OUT OF BLOCK.

         CAUSE         MPTRTM is currently analyzing a bad system log file.

         ACTION        None.  The problem is not an MPTRTM program error.

 17        MESSAGE       MISSING LOG FILES LOGnnnn to LOGnnnn 

         CAUSE         The FOPEN intrinsic failed to open the log files.

         ACTION        The log files are not on the system.  If the log files are on
                       the system, please contact a Hewlett-Packard Support
                       Representative.

 19        MESSAGE       SORRY, THE DISC BLOCK SIZE IS TOO BIG (> maxsize).

         ACTION        Please contact a Hewlett-Packard Support Representative.
                       Include all information listed by the MPTRTM program.

MPTREPT Program Error Messages 

The error and warning messages listed below may result when running the
MPTREPT program.  Any of these errors may indicate some problems with the
MPTREPT program, the MPT message catalog, the MPTPARMS parameter file, or
the MPTOPTNS user option file.

 2         MESSAGE       UNABLE TO OPEN THE 'MPTDB' DATABASE.

         CAUSE         The DBOPEN intrinsic failed.

         ACTION        The MPTDB database must be present on the system.  If it is
                       not, build it by running MPT. If the database is present, make
                       sure the appropriate file equations are set up.  Refer to the
                       IMAGE Data Base Management System Reference Manual 
                       (32215-90003) or TurboIMAGE Data Base Management System 
                       Reference Manual (32215-90050) for further details.  If the
                       problem cannot be resolved, please contact a Hewlett-Packard
                       Support Representative.  Include all information listed by the
                       MPTREPT program.

 4         MESSAGE       UNABLE TO CREATE THE 'SORTSCR' SCRATCH FILE.

         CAUSE         The FOPEN intrinsic failed.

         ACTION        Refer to the Migration Process Guide (30367-90007) for details.
                       If the problem cannot be resolved, please contact a
                       Hewlett-Packard Support Representative.  Include all
                       information listed by the MPTREPT program.

 7         MESSAGE       filesetname REJECTED. TOO MANY FILESETS.

         CAUSE         The maximum number of filesets has been exceeded.

         ACTION        MPT will continue to process a report.  You can generate
                       another report using only those filesets that are of interest
                       or make your fileset descriptions broader.  If the problem
                       cannot be resolved, please contact a Hewlett-Packard Support
                       Representative.  Include all information listed by the MPTREPT
                       program.

 15        MESSAGE       UNABLE TO OPEN THE filename FILE.

         CAUSE         The FOPEN intrinsic failed.

         ACTION        If the MPTPARMS file is missing, restore it from tape and set
                       up the appropriate file equations if applicable.  If the file
                       specified in the error message is not MPTPARMS, refer to the
                       Migration Process Guide (30367-90007) for details.  If the
                       problem cannot be resolved, please contact a Hewlett-Packard
                       Support Representative.  Include all information listed by the
                       MPTREPT program.

          Table I-6.  (cont.) 

 27        MESSAGE       THERE IS NO "=" FOLLOWING THE COMMAND commandname  (COMMAND
                       IGNORED).

         CAUSE         An equal sign is missing in the MPTOPTNS file.

         ACTION        Edit the MPTOPTNS file and place an equal sign after the
                       reported command.

 29        MESSAGE       YOU CAN'T ADD A FILE WITHOUT SPECIFYING THE 'FNAME'
                       PARAMETER.

         CAUSE         MPTREPT did not find the filename in the correct format in the
                       MPTOPTNS file.

         ACTION        Edit the MPTOPTNS file and enter "FNAMES=" in front of the
                       specified filename.

 33        MESSAGE       TOO MANY FILE CRITERIA WERE FOUND. THE REST WILL BE IGNORED.

         ACTION        Please contact a Hewlett-Packard Support Representative.
                       Include all information listed by the MPTREPT program.



MPE/iX 5.0 Documentation