HP 3000 Manuals

Replace a disk that failed after mounting [ Mirrored Disk/iX User's Guide ] MPE/iX 5.0 Documentation


Mirrored Disk/iX User's Guide

Replace a disk that failed after mounting 

   1.  Reply to the console message.

   2.  Invoke VOLUTIL:
__________________________________________________________________________
|                                                                        |
|                                                                        |
|      ?09:09/22/ACKNOWLEDGE MIRRORED PARTNER DISABLED ON LDEV# 32[Y/N]? |
|                                                                        |
|      :REPLY 22,Y                                                       |
|                                                                        |
|      :VOLUTIL                                                          |
|                                                                        |
|      Mirvutil A.00.00, (C) Hewlett-Packard Co., 1990.                  |
|      All Rights Reserved.                                              |
|                                                                        |
|      volutil:                                                          |
|                                                                        |
__________________________________________________________________________

            

   3.  Physically replace the drive that failed.

   4.  Use the VOLUTIL REPLACEMIRRVOL command to resume mirroring on LDEV
       32 for MEMBER2 of the mirrored volume set PROD_SET and the new
       drive with the original LDEV 32:
____________________________________________________
|                                                  |
|                                                  |
|      volutil: REPLACEMIRRVOL PROD_SET:MEMBER2 32 |
|                                                  |
____________________________________________________

            



MPE/iX 5.0 Documentation