Replace a disk that failed after mounting [ Mirrored Disk/iX User's Guide ] MPE/iX 5.0 Documentation
Mirrored Disk/iX User's Guide
Replace a disk that failed after mounting
1. Reply to the console message.
2. Invoke VOLUTIL:
__________________________________________________________________________
| |
| |
| ?09:09/22/ACKNOWLEDGE MIRRORED PARTNER DISABLED ON LDEV# 32[Y/N]? |
| |
| :REPLY 22,Y |
| |
| :VOLUTIL |
| |
| Mirvutil A.00.00, (C) Hewlett-Packard Co., 1990. |
| All Rights Reserved. |
| |
| volutil: |
| |
__________________________________________________________________________
3. Physically replace the drive that failed.
4. Use the VOLUTIL REPLACEMIRRVOL command to resume mirroring on LDEV
32 for MEMBER2 of the mirrored volume set PROD_SET and the new
drive with the original LDEV 32:
____________________________________________________
| |
| |
| volutil: REPLACEMIRRVOL PROD_SET:MEMBER2 32 |
| |
____________________________________________________
MPE/iX 5.0 Documentation