HP 3000 Manuals

X.21 Messages (RJE/V only) [ RJE User/Programmer Reference Manual ] MPE/iX 5.0 Documentation


RJE User/Programmer Reference Manual

X.21 Messages (RJE/V only) 

---------------------------------------------------------------------------------------

           MESSAGE      NODE NOT CONFIGURED 
           CAUSE        If the NODE parameter of the #RJLINE subsystem command has been
                        specified, but the node name cannot be located in the network
                        configuration data base, then this message is displayed in
                        addition to the message LINE ERROR 5.

           ACTION       Use NETCONF.PUB.SYS to add node to remote node table.  Any new
                        communications lines must also be added to the Line
                        Characteristics table.

---------------------------------------------------------------------------------------

           MESSAGE      CONFIGURATION DB ACCESS ERROR 

           CAUSE        This message may be displayed if the NODE parameter of the
                        #RJLINE command is used to warn the user that a network
                        intrinsic error has taken place.  Such an error occurs when RJE
                        has determined from the database that the specified node name
                        has multiple logical devices associated and is attempting to
                        retrieve the line characteristics for each logical devices from
                        the database.  If an error occurs while doing this, then RJE
                        will try to retrieve data for the next logical device on its
                        list.

           ACTION       If a line is opened successfully, no action is required.  But,
                        any incorrect line information which may be causing this
                        warning should be corrected using NETCONF.PUB.SYS. If a line
                        error message appears after this warning, follow the action for
                        that error."

---------------------------------------------------------------------------------------

           MESSAGE      X21 CALLING LINE IDENTIFICATION 

                        calling line identification string 

           CAUSE        If the call connection is ANSWER in the CONNECT parameter of an
                        #RJLINE command then the calling line identification will be
                        displayed on the system console if one is received.  The
                        calling line identification will be either the International
                        Data Number, or the National Number, or the Network Terminal
                        Number, as specified by the X.21 International Numbering plan
                        for public data networks.

           ACTION       No action required.

---------------------------------------------------------------------------------------



MPE/iX 5.0 Documentation